Key result
Increased left atrial wall thickness was associated with post-ablation atrial fibrillation recurrence and electrical reconnection.
Why the study?
Does increased left atrial wall thickness predict atrial fibrillation recurrence and electrical reconnection after radiofrequency ablation?
Cohort (n=86)
Does increased left atrial wall thickness predict atrial fibrillation recurrence and electrical reconnection after radiofrequency ablation?
Increased left atrial wall thickness is associated with a higher risk of atrial fibrillation recurrence and electrical reconnection following radiofrequency ablation.
Answers are grounded in this paper and cite their sources.
LA thickness associated with post-ablation reconnection; hypothesis-generating for thickness-guided strategies in AF.
INTRODUCTION: Radiofrequency (RF) ablation in thicker regions of the left atrium (LA) may require increased ablation energy in order to achieve effective transmural lesions. Consequently, many cases of recurrent atrial fibrillation (AF) postablation may be due to thicker-than-normal atrial tissue. The aim of this study was to test the hypotheses that patients with recurrent AF have thicker tissue overall and that electrical reconnection is more likely in regions of thicker tissue. METHODS AND RESULTS: Retrospective analysis was performed on 86 CT images acquired preoperatively from a cohort of 119 patients who had undergone RF ablation for AF. Of these, 33 patients experienced recurrence of AF within 1 year of initial treatment and 29 returned for a repeat ablation. For each patient, LA wall thickness (LAWT) was measured from the images in 12 anatomical regions using custom software. Patients with recurrent AF had larger LAWT compared to successfully treated patients (1.6 ± 0.6 mm vs. 1.5 ± 0.5 mm, P < 0.001) and reconnection was found to be at regions of thicker tissue (1.6 ± 0.6 mm, P = 0.038) compared to nonreconnected regions (1.5 ± 0.5 mm). The superior right posterior wall of the LA was significantly related to both recurrence (P = 0.048) and reconnection (P = 0.014). CONCLUSION: Increased LAWT has a small but significant effect on postablation recurrence and reconnection. Measures of LAWT may facilitate appropriate dosing of RF energy, but other factors will be critical in transmural lesion formation and ablation success.
No takes yet. Share an insight, caveat, or question.
Inoue et al. (2016) conducted a cohort in Atrial fibrillation (n=86). Increased left atrial wall thickness vs. Normal/thinner left atrial wall thickness was evaluated on Left atrial wall thickness in patients with recurrent atrial fibrillation versus successfully treated patients (p=<0.001). Increased left atrial wall thickness was associated with post-ablation atrial fibrillation recurrence and electrical reconnection.