Key result
Fetal pulmonary artery diameter evaluated via three vessel view correlated linearly with gestational age (r=0.887), while fetal aorta diameter showed a weak correlation (r=0.164).
Why the study?
The three vessel view is not routinely used locally due to lack of expertise and awareness, so normal reference values were needed to improve CHD screening accuracy.
Cross-Sectional (n=56)
Effect estimate: r=0.887
Establishes normal reference ranges for fetal pulmonary artery and aorta diameters between 18-26 weeks of gestation in a Pakistani population to aid in congenital heart disease screening.
Supports reference ranges for fetal pulmonary artery diameter in Pakistani pregnancies; leaves open validation for congenital heart disease screening.
Congenital heart diseases constitute almost 0.8 to 1.2% of newborn illnesses globally however unfortunately 64% of them remained undiagnosed on conventional anamoly scan which uses four chamber view for cardiac evaluation. In developed countries, other than routine anomaly scan, the three vessel view(3VV) has been added to look for any potential outflow tract anomalies which increased the sensitivity of screening CHD however this view is not routinely used in our clinical practice due to lack of expertise and less awareness regarding the importance of this view . We aimed to establish normal reference values of fetal pulmonary and fetal aorta diameter value using 3VV so that its routine use can increase diagnostic accuracy of anamoly scan in our population. Methodology: This is a non probability convenient study investigating healthy pregnant females between 18-26weeks of gestation conducted from 04-02-2022 to 04-08-2022. After formal ethical approval, 56 patients were included in the study. After achieving 3VV,fetal pulmonary artery and fetal aorta diameter were evaluated and mean values were calculated for each gestational week. Results: The mean age of pregnant females included is 27.3 + 4.4 years (range 20 -37 years). The pulmonary artery diameter ranged from 2.3mm at 18 week of gestation to 3.6mm at 26 week of gestation. Fetal PAD is observed to correlate linearly (r=0.887) with gestational age and linear regression equation derived as PAD= (-0.52) +0.15(GA). Mean fetal aortic diameter was calculated ranged from 1.5mm at 18 week of gestation to 1.6mm at 26week of gestation. Fetal aorta diameter correlation with gestational was found to be 0.164 showing weak correlation along with insignificant regression analysis hence the regression equation cannot be formulated for fetal aorta. Conclusion: Normal mean values of fetal pulmonary artery and fetal aorta from 18-26weeks of gestation were calculated. Linear relationship was found between pulmonary artery diameter and gestational age. However weak correlation noted between fetal aorta diameter and gestational age was noted.
No takes yet. Share an insight, caveat, or question.
Nadeem et al. (2022) conducted a cross-sectional in Healthy pregnancy (n=56). Three vessel view (3VV) ultrasound was evaluated on Fetal pulmonary artery and fetal aorta diameter (r=0.887). Fetal pulmonary artery diameter evaluated via three vessel view correlated linearly with gestational age (r=0.887), while fetal aorta diameter showed a weak correlation (r=0.164).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: