In this paper, we revisit acoustic emission (AE) data from an in situ rock fracture experiment conducted at the Underground Research Laboratory (URL) in Manitoba, Canada. The Mine‐By experiment, a large‐scale excavation response test, was undertaken at a depth of 420 m and involved the mechanical excavation of a cylindrical tunnel. During the experiment a small array of 16 Panametrics V103 AE sensors enclosed a 0.7 m × 0.7 m × 1.1 m rectangular prism of Lac du Bonnet granite located in the tunnel wall. The V103 sensors were later calibrated in the laboratory, and a source parameter analysis was undertaken using a spectral fitting method. Corner frequency and moment magnitude were found to be inside the ranges 250 kHz < f c < 490 kHz and −7.5 < M w <−6.8, respectively. Static stress drops ranged from 0.3 to 4 MPa, which is consistent with large seismicity recorded at the URL.