Key result
99mTc-PYP SPECT/CT visualizes biopsy-confirmed myocardial inflammation in drug-resistant atrial fibrillation.
Why the study?
Identifying the etiological factor for the occurrence and maintenance of atrial fibrillation is of paramount clinical importance and necessary for successful treatment.
Case Report (n=1)
Answers are grounded in this paper and cite their sources.
SPECT/CT with 99m Tc-pyrophosphate may be a useful hybrid imaging technique for identifying underlying myocarditis in patients with drug-resistant atrial fibrillation.
Atrial fibrillation is the most common type of cardiac arrhythmia. Identification of an etiological factor for the occurrence and maintenance of atrial fibrillation is of paramount clinical importance and is a necessary condition for successful treatment. The paper describes a clinical case of myocarditis diagnosed in a patient with atrial fibrillation resistant to drug therapy. Additionally, the patient underwent single-photon emission computed tomography/computed tomography with 99m Tc-pyrophosphate to diagnose a myocardial inflammatory process, followed by comparison of results and histological findings.
No takes yet. Share an insight, caveat, or question.
Ilyushenkova et al. (2019) conducted a case report in Atrial fibrillation resistant to drug therapy (n=1). SPECT/CT with 99mTc-pyrophosphate vs. Endomyocardial biopsy (histological findings) was evaluated on Diagnosis of myocardial inflammatory process. Hybrid imaging using SPECT/CT with 99mTc-pyrophosphate successfully visualized a myocardial inflammatory process, verified by histological findings, in a patient with drug-resistant atrial fibrillation.
Synapse has enriched 10 related papers. Consider them for comparative context: