March 6, 2018Artificial Organs

Meta‐Analysis of Time in Therapeutic Range in Continuous‐Flow Left Ventricular Assist Device Patients Receiving Warfarin

View Full Paper
Ask AI
Bookmark
Share

Why the study?

What is the quality of INR control measured by time in therapeutic range (TTR) in adult CF-LVAD patients receiving warfarin?

Population

5 retrospective single-center studies pooling 270 adult patients with continuous-flow left ventricular…

Design

Meta-analysis

Follow-up

9 to 76 person-years

Key result

Warfarin therapy in patients with continuous-flow left ventricular assist devices resulted in a weighted mean time in therapeutic range of 46.6% (95% CI 36.0-57.3%).

Authors

BMBrandon MartinezBYBrenda YikRTRaymond Tran

Discussion

Loading...

Member takes

Overview

Suboptimal TTR (~47%) in CF-LVAD patients signals elevated thromboembolic/bleeding risk; leaves open optimal anticoagulation strategies pending prospective trials.

Study Design

Type

Meta-Analysis (n=270)

Structured PICO

What is the quality of INR control measured by time in therapeutic range (TTR) in adult CF-LVAD patients receiving warfarin?

P
Population
270 adult patients with continuous-flow left ventricular assist devices receiving warfarin, pooled from 5 retrospective studies with 9 to 76 person-years of follow-up.
E
Exposure
Warfarin
O
Outcome
Time in therapeutic range (TTR) calculated using the Rosendaal methodsurrogate

CF-LVAD patients receiving warfarin have a low mean time in therapeutic range (46.6%), highlighting the difficulty of anticoagulation management in this population.

Limitations

  • All included studies were single-center, retrospective investigations
  • High statistical heterogeneity (I2 = 94%)
  • High statistical heterogeneity (I² = 94%)

Cite This Study

Martinez et al. (2018) conducted a meta-analysis in Advanced heart failure with continuous-flow left ventricular assist devices (CF-LVADs) (n=270). Warfarin was evaluated on Time in therapeutic range (TTR) (95% CI 36.0-57.3). Warfarin therapy in patients with continuous-flow left ventricular assist devices resulted in a weighted mean time in therapeutic range of 46.6% (95% CI 36.0-57.3%).

synapsesocial.com/papers/6a5e4acace909d4c3f67f0a6https://doi.org/10.1111/aor.13116
View Full Paper
Ask AI
Bookmark
Share

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Quality of vitamin K antagonist control and outcomes in atrial fibrillation patients: a meta-analysis and meta-regression2014 · 101 citations
  2. 2Increased Thromboembolic Events With Dabigatran Compared With Vitamin K Antagonism in Left Ventricular Assist Device Patients2017 · 101 citations
  3. 3Does heart failure exacerbation increase response to warfarin?A critical review of the literature2006 · 38 citations
  4. 4Effect of Telmisartan on Renal Outcomes2009 · 196 citations
  5. 5Pharmacist-Managed International Normalized Ratio Patient Self-Testing Is Associated with Increased Time in Therapeutic Range in Patients with Left Ventricular Assist Devices at an Academic Medical Center2014 · 53 citations