Key result
Contact force-sensing and non-contact force-sensing ablation catheters demonstrated comparably low incidence rates of atrioesophageal fistula (0.006% vs 0.005%, p=0.69).
Why the study?
Data are limited on the specific incidence of serious adverse events like atrioesophageal fistula associated with contact force versus non-contact force ablation catheters, making direct comparisons difficult.
Does the use of contact force-sensing ablation catheters compared to non-contact force-sensing catheters affect the incidence of atrioesophageal fistula?
Observational
Does the use of contact force-sensing ablation catheters compared to non-contact force-sensing catheters affect the incidence of atrioesophageal fistula?
Contact force-sensing and non-contact force-sensing ablation catheters have a similarly low incidence of atrioesophageal fistula, though high power, force, and long RF duration on the posterior wall appear to be procedural risk factors.
Answers are grounded in this paper and cite their sources.
Reassuringly low fistula rates should not alter catheter selection; observational data leaves open whether contact force-sensing improves esophageal safety.
PURPOSE: There is limited data on the specific incidence of serious adverse events, such as atrioesophageal fistula (AEF), associated with either contact force (CF) or non-CF ablation catheters. Since the actual number of procedures performed with each type of catheter is unknown, making direct comparisons is difficult. The purpose of this study was to assess the incidence of AEF associated with the use of CF and non-CF catheters. Additionally, we aimed to understand the workflow present in confirmed AEF cases voluntarily provided by physicians. METHODS: The number of AEFs for 2014-2017 associated with each type of catheter was extracted from an ablation device manufacturer's complaint database. Proprietary device sales data, a proxy for the total number of procedures, were used as the denominator to calculate the incidence rates. Additional survey and workflow data were systematically reviewed. RESULTS: Both CF and non-CF ablation catheters have comparably low incidence of AEF (0.006 ± 0.003% and 0.005 ± 0.003%, respectively, p = 0.69). CF catheters are the catheter of choice for left atrium (LA) procedures which pose the greatest risk for AEF injury. Retrospective analysis of seven AEF cases demonstrated that high power and force and long RF duration were delivered on the posterior wall of the left atrium in all cases. CONCLUSIONS: CF and non-CF ablation catheters were found to have similar AEF incidence, despite CF catheters being the catheter of choice for LA procedures. More investigation is needed to understand the range of parameters which may create risk for AEF.
No takes yet. Share an insight, caveat, or question.
Calkins et al. (2019) conducted an observational in Atrial fibrillation (undergoing radiofrequency ablation). Contact force-sensing (CF) ablation catheters vs. Non-contact force-sensing (non-CF) ablation catheters was evaluated on Incidence of atrioesophageal fistula (AEF) as a percentage of device sales (p=0.69). Contact force-sensing and non-contact force-sensing ablation catheters demonstrated comparably low incidence rates of atrioesophageal fistula (0.006% vs 0.005%, p=0.69).