April 30, 2014Open Access

Real-time contact force assessment during catheter ablation of atrial fibrillation is associated with shorter procedure times, reduced fluoroscopy exposure, and a higher proportion of durable lesions.

View Full Paper
Ask AI
Bookmark
Share

Why the study?

Does real-time catheter-tissue contact force assessment improve procedural and clinical outcomes in catheter ablation of atrial fibrillation?

Population

Patients undergoing catheter ablation of atrial fibrillation (AF) and experimental models

Design

Review

Key result

Real-time contact force assessment during catheter ablation of atrial fibrillation is associated with shorter procedure times, reduced fluoroscopy exposure, and a higher proportion of durable lesions.

Authors

JKJosef KautznerPPPetr Peichl

Discussion

Loading...

Member takes

Overview

May enhance AF ablation efficiency; hypothesis-generating for lesion durability and requires RCT confirmation before practice change.

Structured PICO

Does real-time catheter-tissue contact force assessment improve procedural and clinical outcomes in catheter ablation of atrial fibrillation?

P
Population
A review of experimental and clinical studies evaluating the efficacy and safety of real-time contact force assessment during catheter ablation for atrial fibrillation.
I
Intervention
Real-time catheter-tissue contact force (CF) assessment technologies

Real-time contact force assessment during AF ablation improves procedural efficiency and may enhance lesion durability and clinical efficacy.

Limitations

  • More robust clinical data are needed to definitively confirm higher success rates of catheter ablation for atrial fibrillation using contact force guidance.

Cite This Study

Kautzner et al. (2014) conducted a review in Atrial Fibrillation. Contact force assessment during catheter ablation vs. Standard ablation without contact force assessment was evaluated. Real-time contact force assessment during catheter ablation of atrial fibrillation is associated with shorter procedure times, reduced fluoroscopy exposure, and a higher proportion of durable lesions.

synapsesocial.com/papers/6a86c6563a1d8ec5fdd3bcefhttps://doi.org/10.4022/jafib.1047
View Full Paper
Ask AI
Bookmark
Share

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Contact Force and Atrial Fibrillation Ablation.2015 · 17 citations
  2. 2Atrial Fibrillation Radiofrequency Ablation: Safety Using Contact Force Catheter In A Low-Volume Centre.2016 · 3 citations
  3. 3Evolution of Force Sensing Technologies2017 · 2 citations
  4. 4Optimizing Contact Force During Ablation of Atrial Fibrillation: Available Technologies and a Look to the Future2016 · 1 citations
  5. 5The symbiosis of contact force catheter use for hybrid ablation for atrial fibrillation2015 · 9 citations