Key result
Radiofrequency ablation successfully terminated frequent premature ventricular complexes originating from the left coronary cusp in a patient with a bioprosthetic aortic valve.
Why the study?
Patients with prosthetic valves are often not considered for radiofrequency ablation of frequent PVCs due to the risk of possible fatal and nonfatal complications.
Is radiofrequency ablation feasible for treating high PVC burden in a patient with a bioprosthetic aortic valve?
Case Report (n=1)
No
Is radiofrequency ablation feasible for treating high PVC burden in a patient with a bioprosthetic aortic valve?
Radiofrequency ablation of frequent PVCs from the left coronary cusp is feasible in a patient with a bioprosthetic aortic valve, though risks must be carefully weighed.
Successful RFA for outflow tract PVCs feasible in prosthetic valve patients; leaves open broader safety and efficacy.
INTRODUCTION Although the catheter ablation of frequent premature ventricular complexes (PVCs) from outflow tracts is reported as a highly successful procedure especially in patients with structurally normal hearts, but some cases create a great challenge. Patients with prosthetic valves often are not considered for radiofrequency ablation (RFA) due to risk of possible fatal and nonfatal complications. CASE SUMMARY We describe a rare experience of performing RFA in this high risk, challenging patient. A 76-years-old man with history of coronary artery bypass graft (CABG) due to previous myocardial infarct (MI) and aortic valve replacement with bioprosthetic valve for his aortic insufficiency was referred to our department due to feeling of suffocation and irregularity of pulse during a flight. RF ablation was scheduled for him due to high PVC burden. PVCs showed LBBB morphology, inferior axis with transition in (V3-V4) leads. After failed attempt of RFA through the right outflow tract (RVOT), PVC was terminated from the left coronary cusp. DISCUSSION This case highlights the fact that efficacy of the radiofrequency ablation in patients with bioprosthetic valves is feasible. It has to be emphasized that in such a challenging case, risk of severe complications should be weighted against its benefit.
No takes yet. Share an insight, caveat, or question.
Taherpour et al. (2020) conducted a case report in Ventricular arrhythmias (frequent PVCs) with bioprosthetic aortic valve (n=1). Radiofrequency ablation was evaluated on Termination of PVCs. Radiofrequency ablation successfully terminated frequent premature ventricular complexes originating from the left coronary cusp in a patient with a bioprosthetic aortic valve.