Key result
Systemic device infection is linked to ~49.7-fold higher in-hospital mortality during transvenous lead extraction.
Why the study?
AF is a recognized driver of cardiovascular morbidity and a risk factor for cardiac device-related complications and transvenous lead extraction, but procedural outcomes and risk factors in this population needed characterization.
Does systemic device infection predict in-hospital mortality in patients with atrial fibrillation undergoing transvenous lead extraction?
Cohort (n=510)
Yes
Does systemic device infection predict in-hospital mortality in patients with atrial fibrillation undergoing transvenous lead extraction?
While transvenous lead extraction is highly successful in AF patients, systemic infection, CKD, and low BMI strongly predict in-hospital mortality.
Background: Atrial fibrillation is the most common arrhythmia and has been described as driver of cardiovascular morbidity and risk factor for cardiac device-related complications, as well as in transvenous lead extraction (TLE). Objectives: Aim of this study was to characterize the procedural outcome and risk-factors of patients with atrial fibrillation (AF) undergoing TLE. Methods: We performed a subgroup analysis of all AF patients in the GALLERY (GermAn Laser Lead Extraction RegistrY) database. Predictors for all-cause mortality were assessed. Results: A total number of 510 patients with AF were identified with a mean age of 74.0 ± 10.3 years. Systemic infection (38.4%) was the leading cause for TLE, followed by local infection (37.5%) and lead dysfunction (20.4%). Most of the patients (45.9%) presented with pacemaker systems to be extracted. The total number of leads was 1181 with a 2.3 ± 0.96 leads/patient. Clinical procedural success was achieved in 97.1%. Occurrence of major complications was 1.8% with a procedure-related mortality of 1.0%. All-cause mortality was high with 5.9% and septic shock being the most common cause. Systemic device infection (OR: 49.73; 95% CI: 6.56−377.09, p < 0.001), chronic kidney disease (CKD; OR: 2.67; 95% CI: 1.01−7.03, p = 0.048) and a body mass index < 21 kg/m2 (OR: 6.6; 95% CI: 1.68−25.87, p = 0.007) were identified as independent predictors for all-cause mortality. Conclusions: TLE in AF patients is effective and safe, but in patients with systemic infection the mortality due to septic shock is high. Systemic infection, CKD and body mass index <21 kg/m2 are risk factors for death in patient with AF undergoing TLE.
No takes yet. Share an insight, caveat, or question.
Chung et al. (2022) conducted a cohort in Atrial fibrillation undergoing transvenous lead extraction (n=510). Systemic device infection vs. Absence of systemic device infection was evaluated on All-cause in-hospital mortality (OR 49.73, 95% CI 6.56-377.09, p=<0.001). Systemic device infection (OR 49.73), BMI <21 kg/m2, and chronic kidney disease were independent predictors of in-hospital all-cause mortality in AF patients undergoing transvenous lead extraction.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: