Why the study?
Current statistical models predicting whether FFR is physiologically significant rely solely on anatomical parameters and lack clinical accuracy, prompting evaluation of whether adding coronary artery flow rate improves predictive capability.
Does the inclusion of coronary artery flow rate (CFR) alongside percent diameter stenosis (%DS) improve the prediction of physiologically significant FFR in coronary artery segments with stenosis?
Observational (n=96)
Yes
Does the inclusion of coronary artery flow rate (CFR) alongside percent diameter stenosis (%DS) improve the prediction of physiologically significant FFR in coronary artery segments with stenosis?
Answers are grounded in this paper and cite their sources.
Adding coronary artery flow rate to anatomical parameters improves the predictive accuracy of statistical models for assessing physiologically significant coronary stenosis.
A non-invasive risk assessment tool capable of stratifying coronary artery stenosis into high and low risk would reduce the number of patients who undergo invasive FFR, the current gold standard procedure for assessing coronary artery disease. Current statistic-based models that predict if FFR is above or below the threshold for physiological significance rely completely on anatomical parameters, such as percent diameter stenosis (%DS), resulting in models not accurate enough for clinical application. The inclusion of coronary artery flow rate (CFR) was added to an anatomical-only logistic regression model to quantify added predictive value. Initial hypothesis testing on a cohort of 96 coronary artery segments with some degree of stenosis found higher mean CFR in a group with low FFR < 0.8 (μ = 2.37 ml/s) compared to a group with high FFR > 0.8 (μ = 1.85 ml/s) (p-value = 0.046). Logistic regression modeling using both %DS and CFR (AUC = 0.78) outperformed logistic regression models using either only %DS (AUC = 0.71) or only CFR (AUC = 0.62). Including physiological parameters in addition to anatomical parameters are necessary to improve statistical based models for assessing high or low FFR.
No takes yet. Share an insight, caveat, or question.
Miller. et al. (2023) conducted an observational in Coronary artery stenosis (n=96). Coronary flow rate (CFR) vs. Percent diameter stenosis (%DS) alone was evaluated on Functionally significant stenosis (FFR ≤ 0.8) per 1 ml/s increase in CFR (OR 2.03, 95% CI 1.29-3.22, p=0.002).
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: