Key result
A deep learning-based pipeline reduced the time needed to obtain clinically applicable right ventricular segmentations by 87% compared to fully manual analysis.
Why the study?
Manual RV delineation on CMR is time-consuming, and few studies have assessed the ability of deep learning-based methods to accelerate clinical practice.
Does a deep learning-based pipeline reduce the time needed for right ventricular segmentations compared to fully manual analysis in clinical CMR scans?
Does a deep learning-based pipeline reduce the time needed for right ventricular segmentations compared to fully manual analysis in clinical CMR scans?
A deep learning-based pipeline for right ventricular segmentation on CMR significantly reduces analysis time by 87% while maintaining clinical utility.
Answers are grounded in this paper and cite their sources.
Deep learning pipeline may shorten RV delineation time in CMR; leaves open prospective validation of accuracy and workflow impact.
Right ventricular (RV) volumes are commonly obtained through time-consuming manual delineations of cardiac magnetic resonance (CMR) images. Deep learning-based methods can generate RV delineations, but few studies have assessed their ability to accelerate clinical practice. Therefore, we aimed to develop a clinical pipeline for deep learning-based RV delineations and validate its ability to reduce the manual delineation time. Quality-controlled delineations in short-axis CMR scans from 1114 subjects were used for development. Time reduction was assessed by two observers using 50 additional clinical scans. Automated delineations were subjectively rated as (A) sufficient for clinical use, or as needing (B) minor or (C) major corrections. Times were measured for manual corrections of delineations rated as B or C, and for fully manual delineations on all 50 scans. Fifty-eight % of automated delineations were rated as A, 42% as B, and none as C. The average time was 6 min for a fully manual delineation, 2 s for an automated delineation, and 2 min for a minor correction, yielding a time reduction of 87%. The deep learning-based pipeline could substantially reduce the time needed to manually obtain clinically applicable delineations, indicating ability to yield right ventricular assessments faster than fully manual analysis in clinical practice. However, these results may not generalize to clinics using other RV delineation guidelines.
No takes yet. Share an insight, caveat, or question.
Åkesson et al. (2023) studied Cardiac magnetic resonance imaging (n=1,164). Deep learning-based right ventricular segmentation pipeline vs. Fully manual delineation was evaluated on Time reduction for obtaining clinically applicable delineations (87% time reduction). A deep learning-based pipeline reduced the time needed to obtain clinically applicable right ventricular segmentations by 87% compared to fully manual analysis.