Answers are grounded in this paper and cite their sources.
Investigates hydrogen embrittlement in X100 welded joints, highlighting vulnerability.
Hydrogen-induced cracking (HIC) is a possible failure mode of high-strength pipeline steel welded joints. The HIC susceptibility of shielded metal arc-welded joint of X100 pipeline steel was investigated using the slow strain rate tensile test (SSRT) under current densities of 2 mA/cm2, 5 mA/cm2, 10 mA/cm2, 20 mA/cm2, and 30 mA/cm2. Hydrogen diffusion behavior, distribution of microstructures, and inclusions in the welded joint were also surveyed and characterized. The SSRT results indicated that the welded joint exhibited a higher hydrogen embrittlement index than the base metal (BM) under the same current density, showing a higher HIC sensitivity than the BM. The weld metal (WM) showed a lower hydrogen diffusivity (5.38 × 10−5 cm2·s−1) than the BM (6.23 × 10−5 cm2·s−1). The martensite–austenite (M-A) constituent area fraction in the WM was higher than that in the coarse-grained heat-affected zone (CGHAZ), fine-grained HAZ (FGHAZ), and BM. The inclusion amount in the WM was larger than that in the BM. In addition, the high HIC vulnerability of the X100 steel welded joint was also associated with a coarse grain size in the WM.
No takes yet. Share an insight, caveat, or question.
Yan et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: