Key result
Intracoronary nitroprusside injection improved angiographic TIMI flow by at least one grade in 82% of patients with slow/no-reflow phenomenon complicating primary PCI (P=0.007).
Why the study?
Does intracoronary nitroprusside injection improve angiographic flow in patients with slow/no-reflow phenomenon complicating primary PCI for AMI?
Observational (n=11)
Does intracoronary nitroprusside injection improve angiographic flow in patients with slow/no-reflow phenomenon complicating primary PCI for AMI?
Intracoronary nitroprusside injection is a feasible and effective technique for improving angiographic flow in patients who develop slow/no-reflow phenomenon during primary PCI for AMI.
Answers are grounded in this paper and cite their sources.
Slow/no-reflow in primary PCI was associated with poor prognosis; leaves open targeted prevention trials.
Slow/no-reflow phenomenon is a serious problem complicating primary percutaneous coronary intervention (PCI) for acute myocardial infarction (AMI) and is associated with a poor prognosis. From January 2002 to November 2002, 11 of the 70 consecutive patients with ST elevation AMI who were subjected to primary PCI using balloon angioplasty and/or stenting developed slow/no-reflow phenomenon (TIMI 1 flow in 2, TIMI 2 in 8, and TIMI 2.5 in 1). They were 10 men and 1 woman, aged 64 +/- 11 years (range, 46-81). The culprit vessels were six in the left anterior descending coronary artery, three in the right coronary artery, one in the left circumflex coronary artery, and one in saphenous vein graft. Multiple bolus doses (100 microg) of nitroprusside were injected into the index artery through the guiding catheter using a 3 ml syringe until the TIMI flow grade improved by at least one grade or the systolic pressure decline below 80 mm Hg (one patient). The total drug dose varied from 100 to 700 microg. Following the drug treatment, angiographic TIMI flow grade improved by at least one grade in 9 (82%) of the 11 patients (P = 0.007). The TIMI frame counts significantly decreased from 36 +/- 17 frame counts to 16 +/- 11 frame counts (P = 0.012). All patients were discharged without major adverse cardiovascular events. Intracoronary bolus injection of nitroprusside using a 3 ml syringe appears to be a feasible, safe, and effective technique for the management of slow/no-reflow phenomenon complicating primary PCI.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2004) conducted an observational in Slow/no-reflow phenomenon complicating primary PCI for acute myocardial infarction (n=11). Intracoronary nitroprusside injection was evaluated on Improvement of angiographic TIMI flow grade by at least one grade (p=0.007). Intracoronary nitroprusside injection improved angiographic TIMI flow by at least one grade in 82% of patients with slow/no-reflow phenomenon complicating primary PCI (P=0.007).
Synapse has enriched 10 related papers. Consider them for comparative context: