To recycle retired series/parallel battery packs, it is necessary to know their state-of-health (SOH) correctly. Unfortunately, voltage imbalances between the cells occur repeatedly during discharging/charging. The voltage ranges for the discharge/charge of a retired series/parallel battery pack are reduced owing to the voltage imbalances between the cells. To determine the accurate SOH of a retired series/parallel battery pack, it is necessary to calculate the total discharge capacity using fully discharging/charging tests. However, a fully discharging/charging test is impossible owing to the reduced voltage range. The SOH of a retired series/parallel battery pack with a voltage imbalance should be estimated within the reduced discharging/charging voltage range. This paper presents a regression analysis of the peak point in the incremental capacity (IC) curve from the fresh state to a 100-cycle aging state. Moreover, the SOH of the considered retired series/parallel battery pack was estimated using a regression analysis model. The error in the SOHs of the retired series/parallel battery pack and linear regression analysis model was within 1%, and hence a good accuracy is achieved.
Lee et al. (2019) studied this question.