Key result
A lower average impedance drop during catheter ablation (lower vs upper third) was associated with a higher risk of 1-year atrial fibrillation recurrence.
Why the study?
Local impedance drop during catheter ablation may guide AF ablation procedures, but whether it predicts 1-year AF recurrence and what threshold is most predictive remained unclear.
Does local impedance drop during catheter ablation predict 1-year AF recurrence in patients with atrial fibrillation?
Cohort (n=242)
Does local impedance drop during catheter ablation predict 1-year AF recurrence in patients with atrial fibrillation?
A threshold of 7.2 ohms for average local impedance drop during atrial fibrillation ablation predicts 1-year clinical recurrence, demonstrating the feasibility of using linked procedural and EHR data to optimize ablation parameters.
Answers are grounded in this paper and cite their sources.
May inform real-time lesion quality assessment during AF ablation; leaves open whether targeting higher impedance drops improves outcomes.
BackgroundLocal impedance drop in cardiac tissue during catheter ablation may be a valuable measure to guide atrial fibrillation (AF) ablation procedures for greater effectiveness.ObjectiveTo assess whether local impedance drop during catheter ablation to treat atrial fibrillation predicts 1-year AF recurrence and what threshold of impedance drop is most predictive.MethodsWe identified patients with AF undergoing catheter ablation in the Mercy healthcare system. We downloaded AF ablation procedural data recorded by the CARTO system from a cloud-based analytical tool (CARTONET) and linked them to individual patient electronic health records. Average impedance drops in anatomical region of right and left pulmonary veins (PV) were calculated. Effectiveness was measured by a composite outcome of repeat ablation, AF re-hospitalization, direct current cardioversion or initialization of a new antiarrhythmic drug post blanking period. The association between impedance drop and 1-year AF recurrence was assessed by logistic regression adjusting for demographics, clinical, and ablation characteristics. Bootstrapping was used to determine the most predictive threshold for impedance drop based on the Youden index.ResultsAmong 242 patients, 23.6% (57) experienced 1-year AF recurrence. Patients in the lower third vs upper third of average impedance drop had a 5.9-fold (95% confidence interval (CI): 1.81-21.8) higher risk of recurrence (37.0% vs 12.5%). The threshold of 7.2 ohms (95% CI: 5.75-7.7) impedance drop best predicted AF recurrence, with sensitivity of 0.73 and positive predictive value (PPV) of 0.33. Patients with impedance drop ≤ 7.2 ohms had 3.5-fold (95% CI: 1.39 - 9.50) higher risk of recurrence than patients with impedance drop > 7.2 ohms and there was no statistical difference in adverse events between the two groups of patients. Sensitivity analysis on right and left WACA impedance drop were consistent.ConclusionAverage impedance drop is a strong predictor of clinical success in reducing AF recurrence but as a single criterion for predicting recurrence only reached 73% sensitivity and 33% PPV. Local impedance drop in cardiac tissue during catheter ablation may be a valuable measure to guide atrial fibrillation (AF) ablation procedures for greater effectiveness. To assess whether local impedance drop during catheter ablation to treat atrial fibrillation predicts 1-year AF recurrence and what threshold of impedance drop is most predictive. We identified patients with AF undergoing catheter ablation in the Mercy healthcare system. We downloaded AF ablation procedural data recorded by the CARTO system from a cloud-based analytical tool (CARTONET) and linked them to individual patient electronic health records. Average impedance drops in anatomical region of right and left pulmonary veins (PV) were calculated. Effectiveness was measured by a composite outcome of repeat ablation, AF re-hospitalization, direct current cardioversion or initialization of a new antiarrhythmic drug post blanking period. The association between impedance drop and 1-year AF recurrence was assessed by logistic regression adjusting for demographics, clinical, and ablation characteristics. Bootstrapping was used to determine the most predictive threshold for impedance drop based on the Youden index. Among 242 patients, 23.6% (57) experienced 1-year AF recurrence. Patients in the lower third vs upper third of average impedance drop had a 5.9-fold (95% confidence interval (CI): 1.81-21.8) higher risk of recurrence (37.0% vs 12.5%). The threshold of 7.2 ohms (95% CI: 5.75-7.7) impedance drop best predicted AF recurrence, with sensitivity of 0.73 and positive predictive value (PPV) of 0.33. Patients with impedance drop ≤ 7.2 ohms had 3.5-fold (95% CI: 1.39 - 9.50) higher risk of recurrence than patients with impedance drop > 7.2 ohms and there was no statistical difference in adverse events between the two groups of patients. Sensitivity analysis on right and left WACA impedance drop were consistent. Average impedance drop is a strong predictor of clinical success in reducing AF recurrence but as a single criterion for predicting recurrence only reached 73% sensitivity and 33% PPV.
No takes yet. Share an insight, caveat, or question.
Coplan et al. (2024) conducted a cohort in Atrial fibrillation (n=242). Lower average impedance drop (lower third) vs. Higher average impedance drop (upper third) was evaluated on 1-year AF recurrence (composite of repeat ablation, AF re-hospitalization, direct current cardioversion or initialization of a new antiarrhythmic drug post blanking period) (OR 5.9, 95% CI 1.81-21.8). A lower average impedance drop during catheter ablation (lower vs upper third) was associated with a higher risk of 1-year atrial fibrillation recurrence.