Key result
HeartMate 3 shows no difference in major infection rates compared to HeartMate II.
RCT (n=1,020)
Absolute Event Rate: 58% vs 56%
p-value: p=0.57
Randomized trial examines infection outcomes in patients with left ventricular assist devices, indicating persistent infection risks despite device advancements.
BACKGROUNDIn a randomized controlled trial (MOMENTUM 3), the HeartMate 3 (HM3) fully magnetically levitated centrifugal-flow left ventricular assist device (LVAD) demonstrated superiority over the HeartMate II (HMII) axial-flow LVAD. These findings were driven by hemocompatibility-related outcomes, but infection-related outcomes were not altered by device choice. In this trial-level analysis, we analyzed the clinical patterns of infection-related outcomes over 2 years of support.METHODSIn MOMENTUM 3, 1,020 patients were implanted with either the HM3 (n = 515) or HMII (n = 505) pump. Clinical characteristics and morbidity- and mortality-related outcomes were evaluated to identify predictors associated with major infectious complications, using univariable and multivariable models.RESULTSThe cumulative number of infections at 2 years was 1,213 (634 HM3 and 579 HMII), and major infection occurred in 58% of patients with the HM3 and 56% of patients with the HMII (p = 0.57). Infections of a local nature unrelated to pump components were most common (n = 681/1,213; 56%), followed by driveline-associated infection (n = 329/1,213; 27%), sepsis (n = 194/1,213; 16%), and other events (n = 9/1,213; 0.7%). Bacterial pathogens were implicated in 806 of 1,213 events (66%); significant predictors of infection included sex (women vs men; hazard ratio [HR]: 1.38, p = 0.003), pre-implant use of intra-aortic balloon pump (HR: 1.33, p = 0.02), pre-implant history of cardiac surgery (HR: 1.28, p = 0.01), and body mass index ≥ 30 (HR: 1.40, p < 0.0001). Most deaths in those with infection occurred owing to non-infectious causes.CONCLUSIONInfection is the most common adverse effect in patients implanted with contemporary continuous-flow LVADs, with most such events unrelated to the pump or its peripheral components. Whether chronic mechanical circulatory devices confer an immunomodulatory effect pre-disposing to infection warrants closer scrutiny to understand and ameliorate this morbidity. In a randomized controlled trial (MOMENTUM 3), the HeartMate 3 (HM3) fully magnetically levitated centrifugal-flow left ventricular assist device (LVAD) demonstrated superiority over the HeartMate II (HMII) axial-flow LVAD. These findings were driven by hemocompatibility-related outcomes, but infection-related outcomes were not altered by device choice. In this trial-level analysis, we analyzed the clinical patterns of infection-related outcomes over 2 years of support. In MOMENTUM 3, 1,020 patients were implanted with either the HM3 (n = 515) or HMII (n = 505) pump. Clinical characteristics and morbidity- and mortality-related outcomes were evaluated to identify predictors associated with major infectious complications, using univariable and multivariable models. The cumulative number of infections at 2 years was 1,213 (634 HM3 and 579 HMII), and major infection occurred in 58% of patients with the HM3 and 56% of patients with the HMII (p = 0.57). Infections of a local nature unrelated to pump components were most common (n = 681/1,213; 56%), followed by driveline-associated infection (n = 329/1,213; 27%), sepsis (n = 194/1,213; 16%), and other events (n = 9/1,213; 0.7%). Bacterial pathogens were implicated in 806 of 1,213 events (66%); significant predictors of infection included sex (women vs men; hazard ratio [HR]: 1.38, p = 0.003), pre-implant use of intra-aortic balloon pump (HR: 1.33, p = 0.02), pre-implant history of cardiac surgery (HR: 1.28, p = 0.01), and body mass index ≥ 30 (HR: 1.40, p < 0.0001). Most deaths in those with infection occurred owing to non-infectious causes. Infection is the most common adverse effect in patients implanted with contemporary continuous-flow LVADs, with most such events unrelated to the pump or its peripheral components. Whether chronic mechanical circulatory devices confer an immunomodulatory effect pre-disposing to infection warrants closer scrutiny to understand and ameliorate this morbidity.
No takes yet. Share an insight, caveat, or question.
Patel et al. (2020) conducted an RCT in Patients implanted with continuous-flow left ventricular assist devices (LVAD) (n=1,020). HeartMate 3 (HM3) LVAD vs. HeartMate II (HMII) LVAD was evaluated on Major infection (p=0.57). The HeartMate 3 LVAD resulted in similar rates of major infection compared to the HeartMate II LVAD over 2 years (58% vs 56%, p=0.57), with most infections being unrelated to the pump components.
Synapse has enriched 2 closely related papers on similar clinical questions. Consider them for comparative context: