Key result
Heart rate decoupling during prolonged cycling was strongly negatively correlated with the exercise-induced change in power output at the first ventilatory threshold, enabling accurate real-time prediction models.
Why the study?
To evaluate relationships between physiological decoupling (heart rate, ventilation, and respiratory frequency) and the durability of the first ventilatory threshold, alongside practical models to predict power output at VT1 during prolonged exercise.
Observational (n=51)
No
Answers are grounded in this paper and cite their sources.
Heart rate and respiratory frequency decoupling during prolonged exercise can predict the durability of the first ventilatory threshold, offering a practical tool for training load monitoring.
Purpose To assess relationships between heart rate (HR), ventilation (̇ V V ˙ E ), and respiratory frequency (F R ) decoupling and durability of the first ventilatory threshold (VT 1 ), and the strength of practical models to predict power output at VT 1 during prolonged exercise. Methods Durability of VT 1 was assessed via measurements of power output at VT 1 before and after ~ 2.5-h of initially moderate-intensity cycling in 51 trained cyclists, as part of four studies published elsewhere. In 12 of those participants, power output at VT 1 was assessed every hour until task failure. For every assessment of power output at VT 1 , HR, F R , and V V ˙ ̇ E was measured at fixed power outputs, and thus decoupling of these variables with power output was determined. Bivariate repeated-measures correlations (r rm ) between decoupling and durability of VT 1 were assessed. Multivariable models were created to predict power output at VT 1 during prolonged exercise using generalised estimating equations. Results Negative correlations were observed between exercise-induced change in power output at VT 1 and HR (r rm = −0.76, P < 0.001) and F R (r rm = −0.40, P = 0.013) decoupling, but not V V ˙ ̇ E decoupling (r rm = −0.25, P = 0.136). The final prediction model, containing baseline VT 1 and peak oxygen uptake, F R decoupling, and an interaction between HR decoupling and exercise duration, effectively predicted real-time VT 1 (mean absolute error, ~ 7.2 W; R 2 , 0.95). Conclusion HR and/or F R decoupling during controlled training sessions may be a practically useful durability assessment. Our prediction models may be an effective means of improving within-session intensity regulation and training load monitoring.
No takes yet. Share an insight, caveat, or question.
Rothschild et al. (2025) conducted an observational in Healthy trained cyclists (n=51). Heart rate and respiratory frequency decoupling during prolonged cycling was evaluated on Correlation between exercise-induced change in power output at the first ventilatory threshold (VT1) and heart rate decoupling (rrm = -0.76, 95% CI -0.87, -0.58, p=<0.001). Heart rate decoupling during prolonged cycling was strongly negatively correlated with the exercise-induced change in power output at the first ventilatory threshold, enabling accurate real-time prediction models.
Synapse has enriched 10 related papers. Consider them for comparative context: