Why the study?
Acute hemodynamic decompensation during ablation of nonidiopathic VT occurs in up to 11% of patients and is associated with high short-term mortality.
Does biventricular mechanical support with Impella RP Flex and Impella 5.5 prevent hemodynamic collapse during ventricular tachycardia ablation in patients with severe biventricular failure?
Case Report (n=2)
Does biventricular mechanical support with Impella RP Flex and Impella 5.5 prevent hemodynamic collapse during ventricular tachycardia ablation in patients with severe biventricular failure?
Biventricular Impella support is a feasible strategy to prevent hemodynamic collapse and allow thorough mapping during high-risk ventricular tachycardia ablation in patients with severe biventricular failure.
Answers are grounded in this paper and cite their sources.
May enable stable VT ablation in severe biventricular failure; hypothesis-generating and requires prospective validation before practice change.
Acute hemodynamic decompensation during ablation of nonidiopathic ventricular tachycardia (VT) occurs in up to 11% of patients and is associated with high short-term mortality.1,2 Mechanisms underlying decompensation are complex and include increases in preload related to fluid infusions (intravenous and from irrigated catheters), positive end-expiratory pressure during mechanical ventilation, worsening inotropy related to the cardiodepressant effects of medications used for general anesthesia, local myocardial effects of ablation, and negative lusitropic effects related to myocardial edema resulting from the procedure itself.
No takes yet. Share an insight, caveat, or question.
Shah et al. (2024) conducted a case report in Refractory ventricular tachycardia with severe biventricular dysfunction/cardiogenic shock (n=2). Biventricular mechanical support (Impella RP Flex and Impella 5.5) was evaluated on Hemodynamic stability and feasibility of VT ablation.
Synapse has enriched 10 related papers. Consider them for comparative context: