Key result
Ultrasound biomicroscopy accurately measured carotid plaque length (r=0.92) and percent stenosis (r=0.75) compared to histology, and pre-plaque PW-Doppler parameters predicted future plaque formation.
Effect estimate: r = 0.92
Ultrasound biomicroscopy accurately measures carotid plaque development and can predict plaque formation based on early blood flow disturbances in a mouse model.
Caution against clinical UBM use for carotid plaque; leaves open further preclinical validation in atherosclerosis models.
Atherosclerosis is responsible for the death of thousands of Americans each year. The carotid constriction model of plaque development has recently been presented as a model for unstable plaque formation in mice. In this study we 1) validate ultrasound biomicroscopy (UBM) for the determination of carotid plaque size, percent stenosis, and plaque development in live animals, 2) determine the sensitivity of UBM in detecting changes in blood flow induced by carotid constriction and 3) test whether plaque formation can be predicted from blood flow parameters measured by UBM. Carotid plaques were induced by surgical constriction in Apo E⁻/⁻ mice. Arteries were imaged bi-weekly by UBM, at which time PW-Doppler measurements of proximal blood flow, as well as plaque length and percent stenosis were determined. Histology was performed 9 weeks post surgery. When compared to whole mount post-mortem measurements, UBM accurately reported carotid plaque length. Percent stenosis, based on transverse B-mode UBM measurements, correlated well with that calculated from histological sections. PW-Doppler revealed that constriction reduced maximum systolic velocity (v(max)) and duration of the systolic velocity peak (t(s)/t(t)). Pre-plaque (2 week post-surgery) PW-Doppler parameters (v(max) and t(s)/t(t)) were correlated with plaque length at 9 weeks, and were predictive of plaque formation. Correlation of initiating PW-Doppler parameters (v(max) and t(s)/t(t)) with resulting plaque length established the degree of flow disturbance required for subsequent plaque development and demonstrated its power for predicting plaque development.
No takes yet. Share an insight, caveat, or question.
Harmon et al. (2012) studied Carotid atherosclerosis (n=39). Ultrasound biomicroscopy (UBM) vs. Histological endpoints was evaluated on Correlation of plaque length between UBM and post-mortem microcaliper measurements (r = 0.92). Ultrasound biomicroscopy accurately measured carotid plaque length (r=0.92) and percent stenosis (r=0.75) compared to histology, and pre-plaque PW-Doppler parameters predicted future plaque formation.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: