Key result
A non-invasive optical technique using a diffused light model demonstrated that the characteristic decorrelation rate is linearly proportional to blood speed and independent of tube diameter.
Why the study?
Non-invasive measurement of arterial blood speed provides vital information on cardiac output and organ perfusion, with blood speed serving as a key indicator of disease progression.
A novel optical method using a diffused light model can non-invasively measure arterial blood speed independent of vessel diameter in a phantom model.
Offers diameter-independent blood speed measurement; leaves open clinical translation pending in vivo validation.
Non-invasive measurement of the arterial blood speed gives important health information such as cardio output and blood supplies to vital organs. The magnitude and change in arterial blood speed are key indicators of the health conditions and development and progression of diseases. We demonstrated a simple technique to directly measure the blood flow speed in main arteries based on the diffused light model. The concept is demonstrated with a phantom that uses intralipid hydrogel to model the biological tissue and an embedded glass tube with flowing human blood to model the blood vessel. The correlation function of the measured photocurrent was used to find the electrical field correlation function via the Siegert relation. We have shown that the characteristic decorrelation rate (i.e., the inverse of the decoherent time) is linearly proportional to the blood speed and independent of the tube diameter. This striking property can be explained by an approximate analytic solution for the diffused light equation in the regime where the convective flow is the dominating factor for decorrelation. As a result, we have demonstrated a non-invasive method of measuring arterial blood speed without any prior knowledge or assumption about the geometric or mechanic properties of the blood vessels.
No takes yet. Share an insight, caveat, or question.
Zhang et al. (2022) studied this question. Non-invasive measurement of arterial blood speed based on diffused light model was evaluated on Characteristic decorrelation rate and its relationship to blood speed. A non-invasive optical technique using a diffused light model demonstrated that the characteristic decorrelation rate is linearly proportional to blood speed and independent of tube diameter.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: