Key result
Both the ANTS and Ottawa GRS instruments validly assessed non-technical skills in simulated anaesthesia (P<0.05 for training level differentiation), though Ottawa GRS had higher reliability.
Observational (n=70)
p-value: p=<0.05
Both the ANTS and Ottawa GRS are valid for evaluating non-technical skills in simulated anaesthesia settings, though the Ottawa GRS demonstrated higher reliability and practical ease of use.
Provides initial validity evidence for ANTS and Ottawa GRS in simulated crises; leaves open clinical adoption pending further validation.
We sought to evaluate the validity of two non-technical skills evaluation instruments, the Anaesthetists’ Non-Technical Skills (ANTS) behavioural marker system and the Ottawa Global Rating Scale (GRS), to apply them to anaesthesia training. The content validity, response process, internal structure, relations with other variables and consequences were described for validity evidence. Simulated crisis management sessions were initiated during which two trained raters evaluated the performance of postgraduate first-, second- and third-year (PGY-1, PGY-2 and PGY-3) anaesthesia residents. The study included 70 participants, composed of 24 PGY-1, 24 PGY-2 and 22 PGY-3 residents. Both instruments differentiated the non-technical skills of PGY-1 from PGY-3 residents (P <0.05). Inter-rater agreement was measured using the intraclass correlation coefficient. For the ANTS instrument, the intraclass correlation coefficients for task management, team-working, situation awareness and decision-making were 0.79, 0.34, 0.81 and 0.70, respectively. For the Ottawa GRS, the intraclass correlation coefficients for overall performance, leadership, problem-solving, situation awareness, resource utilisation and communication skills were 0.86, 0.83, 0.84, 0.87, 0.80 and 0.86, respectively. The Cronbach's alpha for internal consistency of the ANTS instrument was 0.93, and was 0.96 for the Ottawa GRS. There was a high correlation between the ANTS and Ottawa GRS. The raters reported the ease of use of the Ottawa GRS compared to the ANTS. We found sufficient evidence of validity in the ANTS instrument and the Ottawa GRS for the evaluation of non-technical skills in a simulated anaesthesia setting, but the Ottawa GRS was more practical and had higher reliability.
No takes yet. Share an insight, caveat, or question.
Jirativanont et al. (2017) conducted an observational in Anaesthesia training (n=70). Ottawa Global Rating Scale (GRS) and Anaesthetists’ Non-Technical Skills (ANTS) system was evaluated on Differentiation of non-technical skills between PGY-1 and PGY-3 residents (p=<0.05). Both the ANTS and Ottawa GRS instruments validly assessed non-technical skills in simulated anaesthesia (P<0.05 for training level differentiation), though Ottawa GRS had higher reliability.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: