Key result
The trans axillarian bareback approach for TAVI was performed safely with 0 procedural complications in 4 patients with severe aortic stenosis and contraindications to trans-femoral access.
Why the study?
Does the axillarian bareback approach allow safe TAVI implantation in patients with severe aortic stenosis and no other access options?
Case Report (n=4)
Does the axillarian bareback approach allow safe TAVI implantation in patients with severe aortic stenosis and no other access options?
The axillarian bareback approach may be a safe alternative for TAVI in patients with severe aortic stenosis who lack other access options due to peripheral vascular disease or patent LIMA-LAD grafts.
Answers are grounded in this paper and cite their sources.
May serve as an alternative access route in select TAVI patients; leaves open the need for comparative trials to confirm safety.
AIM: to describe the procedural steps and to report the short term follow up of our initial experience with an axillarian bareback Dacron graft based technique that could potentially reduce the rate of vascular and ischemic complications during transcatheter aortic valve implantation in patients with contraindications to trans-femoral approach and with patent left internal mammary arterial graft to left anterior descending coronary artery (LIMA-LAD) or small caliber axillarian/subclavian arteries. METHODS AND RESULTS: Four patients were treated with TAVI implantation with a trans axillarian bareback approach. Three out of four had a patent LIMA-LAD graft. In three patients, femoral approach was not considered as an option for the presence of diffuse peripheral vascular disease, while in one for the small caliber of iliac-femoral arteries. All procedures were performed under general anaesthesia. No procedural complications occurred. CONCLUSIONS: In this initial experience, the axillarian bareback approach technique allowed a safe and successful TAVI implant in a subgroup of patients with a high risk of procedural complications due to the presence of a patent LIMA-LAD or vessels of small caliber. Considering the increasing number of patients referred for TAVI, in the next future the axillarian bareback approach could represent a safer alternative to direct cannulation in patients with severe aortic stenosis with no other access options.
No takes yet. Share an insight, caveat, or question.
Biasco et al. (2015) conducted a case report in Severe aortic stenosis (n=4). Trans axillarian bareback approach for TAVI was evaluated on Procedural complications. The trans axillarian bareback approach for TAVI was performed safely with 0 procedural complications in 4 patients with severe aortic stenosis and contraindications to trans-femoral access.
Synapse has enriched 10 related papers. Consider them for comparative context: