Key result
The use of the Heartstring proximal seal system during off-pump coronary artery bypass grafting did not reduce the incidence of early stroke compared to the aortic no-touch technique.
Why the study?
Severe aortic atherosclerosis is a risk factor for stroke during CABG, prompting evaluation of postoperative neurologic complications after off-pump CABG with a proximal seal system.
Does the Heartstring proximal seal system reduce postoperative neurologic complications compared to the aortic no-touch technique in patients undergoing off-pump CABG?
Cohort (n=729)
No
Does the Heartstring proximal seal system reduce postoperative neurologic complications compared to the aortic no-touch technique in patients undergoing off-pump CABG?
Answers are grounded in this paper and cite their sources.
The Heartstring proximal seal system with epiaortic ultrasonography is a safe alternative to the aortic no-touch technique during off-pump CABG, with no significant difference in neurologic complications.
Severe aortic atherosclerosis is a risk factor for stroke during coronary artery bypass grafting (CABG). The purpose of this study was to evaluate the incidence of postoperative neurologic complications after off-pump CABG (OPCAB) with a proximal seal system (Heartstring).From January 2011 to December 2014, 729 patients underwent isolated OPCAB. The cohort was divided into two groups (Heartstring [HS] and aortic no-touch [NT]). The severity of aortic atherosclerosis (Katz grade) was evaluated by intraoperative epiaortic ultrasonography (EUS). The primary endpoints were postoperative neurologic complications (early stroke and minor events (delirium, transient ischemic attack, and syncope) ), and the secondary endpoints were late major adverse cardiac and cerebrovascular events (MACCEs) and death.The mean age of all patients was 65.1 ± 9.5 years, and a severe Katz grade (IV or V) was demonstrated to be an independent risk factor of long-term mortality (HR 3.53; 95% CI 1.06-11.75; P = 0.04) and MACCEs (HR 2.41; 95% CI 1.19-4.92; P = 0.02), but no significant differences were found for early stroke (0.9% versus 1.7%; P = 0.53) and minor neurologic complications (14.6% versus 9.9%; P = 0.05) between the groups regardless of the Katz grade. The 5-year overall survival rate did not differ significantly between the groups (90.9% versus 87.6%; P = 0.61).Although a higher Katz grade was identified as an independent risk factor of death and MACCEs, the HS group was not inferior in terms of neurologic complications regardless of the Katz grade. Therefore, the Heartstring system might be safely and efficiently used with EUS to decrease the incidence of neurologic complications.
No takes yet. Share an insight, caveat, or question.
Kim et al. (2019) conducted a cohort in Coronary artery disease requiring isolated off-pump coronary artery bypass grafting (n=729). Heartstring proximal seal system vs. Aortic no-touch technique was evaluated on Early stroke (OR 0.44, 95% CI 0.11-1.75, p=0.53). The use of the Heartstring proximal seal system during off-pump coronary artery bypass grafting did not reduce the incidence of early stroke compared to the aortic no-touch technique.