This paper proposes a novel antiwindup method of current regulator for the drive system of a surface-mounted permanent-magnet synchronous motor at flux-weakening region. It is designed in conjunction with the synchronous-frame proportional and integral current regulator and the space vector pulse width modulation. The difference between the regulator output voltage and the saturated voltage on the q-axis of the regulator is used for flux-weakening control, which modifies the d-axis current reference. With this method, the antiwindup and the flux-weakening control can be achieved simultaneously. Since the proposed method utilizes the dc-link voltage more efficiently, it makes the motor generate higher output torque than the conventional antiwindup and/or flux-weakening control methods under the same voltage and current limitation. The effectiveness of this method is confirmed by computer simulations and experiments