Answers are grounded in this paper and cite their sources.
Determining how many soil-moisture sensors are needed and where they should be placed remains a persistent challenge in smart irrigation, particularly in fields where dense ground observations are not available before deployment. Because the value of these sensors depends on their ability to capture the dominant spatial and temporal patterns of water availability, non-representative placement may bias irrigation decisions and contribute to over-irrigation in some areas and water stress in others. In practice, many existing studies and on-farm deployments still rely on expert judgement, coarse management units, or ad hoc sampling schemes with limited quantitative support for selecting both the number of sensors and their representative locations. In this context, the present study proposes a field-scale, pre-deployment workflow for delineating homogeneous management zones and identifying candidate soil-moisture sensor locations in a 20-ha field in north-central Morocco. The workflow integrates soil information, including texture and key physico-chemical attributes derived from three soil profiles sampled at two depth intervals (0–30 and 30–60 cm), DEM-derived terrain attributes, hydro-climatic background variables, and the exclusion of permanently occupied areas within a common spatial framework. Fuzzy c-means clustering was applied to this multi-source feature space, and the number of zones was assessed using complementary internal validity indices, including Xie-Beni, Davies-Bouldin, Silhouette, Calinski-Harabasz, fuzzy partition coefficient, and entropy. Under the adopted settings, these diagnostics consistently supported a two-zone solution. Candidate sensor locations were then ranked within each zone using a boundary-aware hybrid score that combines fuzzy membership, membership purity, distance from zone boundaries, and a minimum terrain buffer. The study therefore provides a transparent field-scale procedure for delineating candidate management zones and identifying candidate soil-moisture sensor locations from multi-source environmental data under data-scarce conditions. In the 20-ha study field, the analysis supported a parsimonious two-node first-deployment configuration, with one candidate sensor location per homogeneous zone. Because no independent in situ soil-moisture validation was available, their hydrological representativeness, temporal stability, and operational value remain to be assessed through subsequent multi-season field monitoring.
No takes yet. Share an insight, caveat, or question.
Amraouy et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: