Case report reveals effective management of intrathecal catheter placement in a laboring primigravida, suggesting improved outcomes through careful monitoring.
Background Unintentional intrathecal catheter placement is a recognized complication of labor neuraxial analgesia. Although continuous spinal analgesia (CSA) may be used as a management option, prompt recognition, careful catheter management, and close monitoring are required to prevent complications such as severe spinal anesthesia. Case presentation A 31-year-old primigravida underwent combined spinal-epidural analgesia for labor pain. Intrathecal catheter placement was diagnosed after a test dose was administered based on hypotension, motor weakness, sensory block, and glucose-positive aspirated fluid. The catheter was managed as CSA with fentanyl-based analgesia under strict monitoring. Although frequent breakthrough pain required rescue boluses, the vaginal delivery was achieved uneventfully. The patient developed a post-dural puncture headache that resolved after an epidural blood patch. Conclusions This case illustrates the importance of early recognition of inadvertent intrathecal catheter placement and demonstrates that safe labor analgesia can be achieved through conversion to CSA with careful catheter management and close monitoring.
No takes yet. Share an insight, caveat, or question.
Watanabe et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: