Key result
Tei index measured by double pulse Doppler was higher in adults with left ventricular diastolic dysfunction compared to those with normal function.
Why the study?
Does the Tei index measured by double pulse Doppler technique accurately evaluate left ventricular diastolic function in adult health examinations?
Cross-Sectional (n=113)
Does the Tei index measured by double pulse Doppler technique accurately evaluate left ventricular diastolic function in adult health examinations?
Double pulse Doppler measurement of the Tei index correlates with traditional diastolic function parameters and may improve the diagnosis of left ventricular diastolic dysfunction in adult health screenings.
Answers are grounded in this paper and cite their sources.
May support Tei index for adult diastolic assessment; leaves open clinical adoption pending validation studies.
目的:探讨双脉冲多普勒技术测量Tei指数在成人健康体检中评估左室舒张功能的应用价值。方法:选取体检中心健康成人113例,根据脉冲多普勒二尖瓣下血流E/A值及组织多普勒二尖瓣环运动速度e’/a’比值分为组1 (41例完全正常)、组2 (40例E/A、e’/a’ 1而e’/a’ 1, e'/a' < 1). Three groups were measured by double pulse Doppler synchronous of left ventricular function, Tei index and E peak early diastolic mitral flow velocity of mitral annulus E ratio (E/e) and other parameters, and SPSS 19 statistical software was used for data analysis. Results: The Tei index in group 3 and group 2 were significantly higher than that in group 1, and there were differences between the three groups (P < 0.05). The group 2 was higher than group 1. Tei index has correlation with isovolumic IVRT, early diastolic mitral flow E, mitral annulus tissue Doppler e' (septal and lateral wall side) and E/A (P < 0.05). Diastolic dysfunction has a strong correlation with hypertension and family history of diabetes, smoking (1 packs/day) and alcohol, staying up late and sleep poorly, work pressure and other mental factors, obesity, lacking of exercise. Conclusion: Double pulse Doppler can measure Tei index synchronously, and improve the accuracy of diagnosis of left ventricular diastolic dysfunction.
No takes yet. Share an insight, caveat, or question.
荣泉 杨 (2017) conducted a cross-sectional in Left ventricular diastolic dysfunction (n=113). Double pulse Doppler measurement of Tei index vs. Normal diastolic function (Group 1) was evaluated on Tei index differences among groups (p=<0.05). Tei index measured by double pulse Doppler was higher in adults with left ventricular diastolic dysfunction compared to those with normal function.
Synapse has enriched 10 related papers. Consider them for comparative context: