Answers are grounded in this paper and cite their sources.
A hyperspectral imaging system was demonstrated based on two acousto-optic tunable filters (AOTFs). Efficient regulation of the incoherent beam was executed by means of the wide-angular regime of Bragg diffraction in the birefringent materials. A double-filtering process was achieved when these two AOTFs operated with a central wavelength difference. In comparison with the single-filtering method, the spectral bandwidth was greatly compressed, giving an increment of 42.02% in spectral resolution at the wavelength of 651.62 nm. Experimental results and theoretical calculations are basically identical. Furthermore, the sidelobe was found to be suppressed by the double-filtering process with the first order maximum decreased from -9.25 dB to -22.35 dB. The results indicated high spectral resolution and high spectral purity were obtained simultaneously from this method. The basic spectral resolution performance was examined with a didymium glass by this configuration. We present our experimental methods and the detailed results obtained.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2016) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: