Key result
EntropyAF algorithm improves AF detection over COSEn, reaching an AUC of ~98%.
Why the study?
Existing entropy-based atrial fibrillation detectors applied for short-term ECG analysis suffer from several limitations.
Does the EntropyAF algorithm improve the classification accuracy of atrial fibrillation in wearable ECG recordings compared to previous entropy-based methods?
Does the EntropyAF algorithm improve the classification accuracy of atrial fibrillation in wearable ECG recordings compared to previous entropy-based methods?
The new EntropyAF algorithm provides a conceptually simple, computationally efficient, and highly accurate method for scanning continuous wearable ECGs to detect atrial fibrillation.
Answers are grounded in this paper and cite their sources.
EntropyAF may improve wearable AF detection; hypothesis-generating and requires prospective validation before clinical use.
Entropy-based atrial fibrillation (AF) detectors have been applied for short-term electrocardiogram (ECG) analysis. However, existing methods suffer from several limitations. To enhance the performance of entropy-based AF detectors, we have developed a new entropy measure, named EntropyAF, which includes the following improvements: (1) use of a ranged function rather than the Chebyshev function to define vector distance, (2) use of a fuzzy function to determine vector similarity, (3) replacement of the probability estimation with density estimation for entropy calculation, (4) use of a flexible distance threshold parameter, and (5) use of adjusted entropy results for the heart rate effect. EntropyAF was trained using the MIT-BIH Atrial Fibrillation (AF) database, and tested on the clinical wearable long-term AF recordings. Three previous entropy-based AF detectors were used for comparison: sample entropy (SampEn), fuzzy measure entropy (FuzzyMEn) and coefficient of sample entropy (COSEn). For classifying AF and non-AF rhythms in the MIT-BIH AF database, EntropyAF achieved the highest area under receiver operating characteristic curve (AUC) values of 98.15% when using a 30-beat time window, which was higher than COSEn with AUC of 91.86%. SampEn and FuzzyMEn resulted in much lower AUCs of 74.68% and 79.24% respectively. For classifying AF and non-AF rhythms in the clinical wearable AF database, EntropyAF also generated the largest values of Youden index (77.94%), sensitivity (92.77%), specificity (85.17%), accuracy (87.10%), positive predictivity (68.09%) and negative predictivity (97.18%). COSEn had the second-best accuracy of 78.63%, followed by an accuracy of 65.08% in FuzzyMEn and an accuracy of 59.91% in SampEn. The new proposed EntropyAF also generated highest classification accuracy when using a 12-beat time window. In addition, the results from time cost analysis verified the efficiency of the new EntropyAF. This study showed the better discrimination ability for identifying AF when using EntropyAF method, indicating that it would be useful for the practical clinical wearable AF scanning.
No takes yet. Share an insight, caveat, or question.
Zhao et al. (2018) studied Atrial fibrillation (n=35). EntropyAF algorithm vs. Previous entropy methods (COSEn, SampEn, FuzzyMEn) was evaluated on Area under the receiver operating characteristic curve (AUC) for classifying AF and non-AF rhythms using a 30-beat time window (p=<0.01). The EntropyAF algorithm improved the detection of atrial fibrillation compared to the COSEn method, achieving an AUC of on the MIT-BIH database.