Reliability is crucial in industrial applications such as distributed energy systems, motor drives, and HVDC, where continuous operation is mandatory. Multilevel inverters often face failures in power switches, especially IGBTs, making fault-tolerant designs essential. This paper introduces a topology that addresses faults in both inverter legs with minimal additional components. The proposed design ensures inherent flying capacitor voltage balancing under normal and post-fault conditions through an optimized switching scheme. It handles both short-circuit and open-circuit faults while maintaining five-level operation even after a fault in the flying capacitor leg, which is a key advantage. Efficiency analysis under healthy and faulty conditions is performed using PLECS software. The inverter is validated through MATLAB simulations and experimental tests with an R-L load were performed. Results confirm reliable performance under fault conditions. Finally, reliability analysis using the Markov chain method demonstrates the robustness of the proposed topology.