Acute mountain sickness (AMS) is a common condition that affects people that ascend too rapidly to high altitude. It is typically assessed with the Lake Louise AMS Self-report Score (LLSelf) that uses a categorical numeric rating scale to answer five questions addressing AMS-related symptoms, such as headache. A 100-mm visual analog scale (VAS) is commonly used to assess subjective phenomena such as pain, but this scale has never been used for the self-assessment of AMS. The purpose of this study was to compare a VAS score to the total LLSelf and to evaluate the test-retest and interrater reliability of the VAS when used as an assessment of AMS. Participants (N = 356) completed both the LLSelf and the VAS on the summit of Mt. Whitney (4419 m). There was a significant relationship (r = 0.65, p < 0.01) between the LLSelf (2.8 +/- 2.0, mean +/- SD) and the VAS (14.4 +/- 14.1 mm). Fifty-seven participants were randomly selected for reliability testing of the VAS. Both test-retest reliability (ICC = 0.996, 95% CI = 0.992 to 0.998) and interrater reliability (ICC = 1.000, 95% CI = 0.999 to 1.000) were high. The mean difference in the VAS score between tests was <1 mm, as was the difference between raters. These results demonstrate excellent reliability for the VAS as an assessment of AMS.
No takes yet. Share an insight, caveat, or question.
Wagner et al. (2007) studied this question.
Synapse has enriched one closely related paper. Consider it for comparative context: