Key result
PICC line migration to the sinoatrial node causes reversible sinus arrest and asystole.
Case Report (n=1)
No
Mechanical irritation of the sinoatrial node by a migrated central venous catheter should be considered as a reversible cause of new-onset sinus arrest and asystole in critical care settings.
Consider migrated PICC in unexplained sinus arrest; single case leaves open prospective confirmation.
BACKGROUND: Transient bradycardia in the critical care setting is frequently caused by hypoxemia or oropharyngeal manipulation. Central lines have been associated with a variety of cardiac arrhythmias, but sinus arrest and asystole have not been previously reported. METHODS: A 38-year-old woman with multisystem organ failure had several episodes of prolonged sinus arrest, slow junctional escape rhythm, and periods of asystole lasting over 6 seconds. The cause of the repetitive bradyarrhythmia was evaluated by clinical observation including the response to parasympatholytic agents, by detailed analysis of rhythm strips, and review of cardiac imaging studies. RESULTS: The episodes of bradycardia did not coincide with orotracheal manipulation, were not prevented by escalating doses of glycopyrrolate, and were not accompanied by AV conduction disturbance as is frequently seen during a transient increase in vagal tone. Review of the patient's chest X-ray and chest CT revealed that the tip of a peripherally inserted central catheter migrated to the vicinity of the sinoatrial node. Removal of the catheter resulted in prompt resolution of the episodes of sinus arrest. CONCLUSIONS: This case demonstrates that migration of a peripherally inserted central catheter to the sinoatrial node can provoke prolonged sinus bradycardia, sinus arrest and asystole.
No takes yet. Share an insight, caveat, or question.
Nazinitsky et al. (2013) conducted a case report in Multisystem organ failure (n=1). Peripherally inserted central catheter (PICC) migration was evaluated on Resolution of sinus arrest and asystole upon catheter removal. Migration of a peripherally inserted central catheter to the sinoatrial node provoked prolonged sinus bradycardia, sinus arrest, and asystole, which promptly resolved upon catheter removal.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: