Key result
HPSD ablation linked to ~66% shorter ablation time vs standard power in typical atrial flutter.
Why the study?
High-power short-duration ablation has been explored for pulmonary vein isolation, but data were lacking on its use for other arrhythmias, including typical atrial flutter.
Does high-power short-duration radiofrequency ablation reduce procedure time and analgesic requirements in patients undergoing cavotricuspid isthmus ablation for typical atrial flutter?
Cohort (n=114)
No
Does high-power short-duration radiofrequency ablation reduce procedure time and analgesic requirements in patients undergoing cavotricuspid isthmus ablation for typical atrial flutter?
High-power short-duration ablation for typical atrial flutter is safe and significantly reduces radiofrequency delivery time and patient analgesic requirements compared to standard techniques.
May shorten CTI ablation time and reduce fentanyl needs; leaves open long-term outcomes pending randomized trials.
BackgroundHigh-power short-duration (HPSD) ablation has been explored for pulmonary vein isolation. Early data suggest similar efficacy with shorter procedure times and perhaps greater safety. Data are lacking on the use of this ablation strategy for other arrhythmias.ObjectiveThe purpose of this study was to evaluate the safety, efficacy, and clinical outcomes of HPSD ablation in patients with typical atrial flutter compared to those undergoing ablation with conventional settings.MethodsConsecutive patients undergoing cavotricuspid isthmus (CTI) ablation using standard power settings were compared to those performed after transitioning to HPSD ablation. Demographics, procedural details, and ablation outcomes were prospectively collected. The primary endpoint was duration of radiofrequency energy delivery. Secondary endpoints were radiation duration and analgesia requirements.ResultsA total of 114 consecutive subjects undergoing CTI ablation (57 standard power, 57 HPSD) were included. HPSD ablation and electroanatomic mapping/contact force (EAM/CF) use were associated with 66% (95% confidence interval [CI] 58%–73%) and 50% (95% CI 37%–60%) shorter ablation times compared to standard power and not using EAM/CF, respectively. Patients in the HPSD group required 50 mcg less fentanyl relative to the standard ablation arm after adjusting for sex, age, and comorbidities (P = .048). At a median follow-up of 6 months, 4 patients (7%) in the standard arm had recurrence of atrial flutter, compared to none in HPSD group (P = .057).ConclusionHPSD is a safe and effective approach to CTI ablation. This strategy may reduce ablation time and analgesia requirements. Larger studies and longer follow-up are needed to further evaluate this strategy. High-power short-duration (HPSD) ablation has been explored for pulmonary vein isolation. Early data suggest similar efficacy with shorter procedure times and perhaps greater safety. Data are lacking on the use of this ablation strategy for other arrhythmias. The purpose of this study was to evaluate the safety, efficacy, and clinical outcomes of HPSD ablation in patients with typical atrial flutter compared to those undergoing ablation with conventional settings. Consecutive patients undergoing cavotricuspid isthmus (CTI) ablation using standard power settings were compared to those performed after transitioning to HPSD ablation. Demographics, procedural details, and ablation outcomes were prospectively collected. The primary endpoint was duration of radiofrequency energy delivery. Secondary endpoints were radiation duration and analgesia requirements. A total of 114 consecutive subjects undergoing CTI ablation (57 standard power, 57 HPSD) were included. HPSD ablation and electroanatomic mapping/contact force (EAM/CF) use were associated with 66% (95% confidence interval [CI] 58%–73%) and 50% (95% CI 37%–60%) shorter ablation times compared to standard power and not using EAM/CF, respectively. Patients in the HPSD group required 50 mcg less fentanyl relative to the standard ablation arm after adjusting for sex, age, and comorbidities (P = .048). At a median follow-up of 6 months, 4 patients (7%) in the standard arm had recurrence of atrial flutter, compared to none in HPSD group (P = .057). HPSD is a safe and effective approach to CTI ablation. This strategy may reduce ablation time and analgesia requirements. Larger studies and longer follow-up are needed to further evaluate this strategy.
No takes yet. Share an insight, caveat, or question.
Golian et al. (2020) conducted a cohort in Typical atrial flutter (n=114). High-power short-duration (HPSD) radiofrequency ablation vs. Standard power radiofrequency ablation (30 W for 30-40 seconds) was evaluated on Duration of radiofrequency energy delivery (ablation time in minutes) (66% reduction, 95% CI 58%-73%, p=<0.001). High-power short-duration radiofrequency ablation reduced total ablation time by 66% compared to standard power settings in patients with typical atrial flutter.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: