Key result
High-power short-duration ablation cuts AF recurrence ~49% and shortens procedure time vs low-power long-duration.
Why the study?
HPSD ablation has emerged as an alternative to traditional LPLD ablation, but its safety and efficacy remain controversial.
Does high-power short-duration (HPSD) catheter ablation reduce procedure time and atrial fibrillation recurrence in patients with atrial fibrillation compared to low-power long-duration (LPLD) ablation?
Meta-Analysis (n=1,024)
Does high-power short-duration (HPSD) catheter ablation reduce procedure time and atrial fibrillation recurrence in patients with atrial fibrillation compared to low-power long-duration (LPLD) ablation?
Effect estimate: MD -20.33 (95% CI -30.46 to -10.21)
p-value: p=<0.0001
High-power short-duration ablation significantly reduces procedure times and atrial fibrillation recurrence compared to conventional low-power long-duration ablation, without increasing the risk of complications.
Supports HPSD preference for AF ablation; reinforces RCT evidence for routine use.
Background High-power short-duration (HPSD) ablation has emerged as an alternative to traditional low-power long-duration (LPLD) ablation. However, the safety and efficacy of HPSD remain controversial. This study aimed to evaluate the effectiveness and safety of HPSD in the ablation treatment of atrial fibrillation (AF). Methods Randomized controlled trials (RCTs) comparing high-power short-duration (HPSD) and low-power long-duration (LPLD) ablation were retrieved from PubMed, Web of Science, EMBASE, and the Cochrane Library up to 20 May 2025. Statistical analysis was performed using RevMan 5.4 software. The risk ratio (RR) was used as the effect size for dichotomous variables, and the mean and standard deviation were used as the effect sizes for continuous variables. Results A total of eight RCTs involving 1,024 patients were included. HPSD was significantly associated with a reduction in total procedure time [mean differences (MD), −20.33; 95% CI: −30.46 to −10.21; P < 0.0001], pulmonary vein isolation time (MD, −22.01; 95% CI: −27.10 to −16.95; P < 0.00001), radiofrequency time (MD, −10.38; 95% CI: −12.47 to −8.29; P < 0.00001), and AF recurrence (RR, 0.51; 95% CI: 0.36–0.74; P = 0.0004, I 2 = 14%, P = 0.32). However, no significant differences were observed between HPSD and LPLD ablation in all atrial arrhythmias recurrence (RR, 1.06; 95% CI: 0.75–1.49; P = 0.74, I 2 = 40%, P = 0.15), the incidence of esophageal lesions (RR, 1.21; 95% CI: 0.55–2.64; P = 0.63), any complications (RR, 1.37; 95% CI: 0.76–2.45; P = 0.29), first-pass left pulmonary vein (LPV) isolation (RR, 0.96; 95% CI: 0.91–1.01; P = 0.10, I 2 = 47%, P = 0.11), and first-pass right pulmonary vein (RPV) isolation (RR, 1.01; 95% CI: 0.69–1.48; P = 0.97, I 2 = 75%, P = 0.003). Conclusion Compared with LPLD ablation, HPSD ablation was significantly associated with a reduction in total procedure time, PVI time, and radiofrequency time. HPSD ablation did not increase the risk of complications compared with LPLD ablation, but it may be underpowered to detect rare adverse events, necessitating additional large-scale RCTs to validate the safety profile of HPSD. Systematic Review Registration https://www.crd.york.ac.uk/PROSPERO/view/CRD42023471797 , PROSPERO CRD42023471797.
No takes yet. Share an insight, caveat, or question.
He et al. (2025) conducted a meta-analysis in Atrial fibrillation (n=1,024). High-power short-duration (HPSD) ablation vs. Low-power long-duration (LPLD) ablation (20-35 W, 20-40 s per lesion) was evaluated on Total procedure time (MD -20.33, 95% CI -30.46 to -10.21, p=<0.0001). High-power short-duration ablation significantly reduced total procedure time (MD -20.33) and atrial fibrillation recurrence (RR 0.51) compared to low-power long-duration ablation.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: