Key result
HPSD radiofrequency ablation reduces AF recurrence ~46% vs LPLD ablation.
Why the study?
Randomized trials comparing HPSD and LPLD radiofrequency ablation for pulmonary vein isolation showed conflicting results regarding AF recurrences and limited data on complications.
Does high-power-short-duration radiofrequency ablation reduce atrial fibrillation recurrence and procedural times compared to low-power-long-duration ablation in patients with atrial fibrillation?
Meta-Analysis (n=424)
Does high-power-short-duration radiofrequency ablation reduce atrial fibrillation recurrence and procedural times compared to low-power-long-duration ablation in patients with atrial fibrillation?
Effect estimate: RR 0.54 (95% CI 0.38-0.79)
Absolute Event Rate: 16.3% vs 30.1%
p-value: p=0.001
High-power-short-duration radiofrequency ablation significantly reduces atrial fibrillation recurrence and procedural times without increasing complications compared to low-power-long-duration ablation.
BACKGROUND: High-power-short-duration (HPSD) radiofrequency (RF) ablation is a viable alternative to low-power-long-duration (LPLD) RF for pulmonary vein isolation (PVI). Nevertheless, trials showed conflicting results regarding atrial fibrillation (AF) recurrences and few data concerning complications. Therefore, we conducted a meta-analysis of randomized trials comparing HPSD versus LPLD. METHODS: We systematically searched the electronic databases for studies published from inception to March 31, 2023 focusing on HPSD versus LPLD. The study endpoints were AF recurrence, procedural times and overall complications. RESULTS: Five studies enrolling 424 patients met the inclusion criteria (mean age 61.1 years; 54.3% paroxysmal AF; mean LVEF 58.2%). Compared to LPLD, HPSD showed a significantly lower AF recurrence rate [16.3% vs. 30,1%; RR: 0.54 (95% CI: 0.38-0.79); p = 0.001] at a mean 10.9 months follow-up. Moreover, HPSD led to a significant reduction in total procedural time [MD: -26.25 min (95%CI: -42.89 to -9.61); p = 0.002], PVI time [MD: -26.44 min (95%CI: -38.32 to -14.55); p < 0.0001], RF application time [MD: -8.69 min (95%CI: -11.37 to -6.01); p < 0.00001] and RF lesion number [MD: -7.60 (95%CI: -10.15 to -5.05); p < 0.00001]. No difference was found in either right [80.4% vs. 78.2%; RR: 1.04 (95% CI: 0.81-1.32); p = 0.77] or left [92.3% vs. 90.2%; RR: 1.02 (95% CI: 0.94-1.11); p = 0.58] first-pass isolation and overall complications [6% vs. 3.7%; RR: 1.45 (95%CI: 0.53-3.99); p = 0.47] between groups. CONCLUSION: In our metanalysis of randomized trials, HPSD ablation appeared to be associated to a significantly improved freedom from AF and shorter procedures, without increasing the risk of complications.
No takes yet. Share an insight, caveat, or question.
Parlavecchio et al. (2023) conducted a meta-analysis in atrial fibrillation (n=424). High-power-short-duration (HPSD) radiofrequency ablation vs. Low-power-long-duration (LPLD) radiofrequency ablation was evaluated on atrial fibrillation recurrence (RR 0.54, 95% CI 0.38-0.79, p=0.001). HPSD radiofrequency ablation significantly reduced atrial fibrillation recurrence compared to LPLD ablation (16.3% vs 30.1%; RR 0.54; 95% CI 0.38-0.79; p=0.001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: