Key result
A novel multistage deep residual network achieved a sensitivity of 90% and 97.1% for supraventricular and ventricular beats, respectively, and 81% for seizure detection.
Why the study?
Biomedical datasets frequently present class imbalance problems, creating a need for automated and efficient anomaly detection in time-series signals such as ECG and EEG.
Does a multistage deep residual network improve automated arrhythmia and seizure detection in ECG and EEG signals?
Does a multistage deep residual network improve automated arrhythmia and seizure detection in ECG and EEG signals?
A novel multistage deep residual network provides highly sensitive and computationally efficient automated detection of arrhythmias and seizures from ECG and EEG signals without requiring preprocessing.
May facilitate efficient automated detection; leaves open prospective clinical validation before adoption.
In this paper, we propose a novel biomedical cyberphysical system for automated and efficient arrhythmia and seizure detection in the time-series biomedical signals such as electrocardiogram (ECG) and electroencephalography (EEG). We use a novel multilayer, automated, and multistage deep residual network for the anomaly detection in the biomedical signals. Generally, the biomedical datasets have class imbalance problem; hence, we leverage the concepts of undersampling techniques to address this issue. The proposed algorithm is validated on the publicly available benchmark MIT-BIH Arrhythmia and CHB-MIT Scalp databases. The results show a significant improvement in terms of the sensitivity of 90% and 97.1% for supraventricular and ventricular beats for best fold, respectively. The accuracy obtained is at par with most of the state-of-the-art methods, and in particular, for the supraventricular beats, the proposed method outperforms all but one state-of-the-art method. The advantage of the proposed method is that it gives reliable results with EEG samples of small duration and, as opposed to other state-of-the-art methods, it does not involve any preprocessing, hence computationally efficient. Additionally, the proposed algorithm provides 81% sensitivity for seizure detection in EEG signals, which is comparable to existing deep learning methods.
No takes yet. Share an insight, caveat, or question.
Pandey et al. (2019) studied Arrhythmia and seizure. Multistage deep residual network vs. State-of-the-art methods was evaluated on Sensitivity for supraventricular and ventricular beats, and seizure detection. A novel multistage deep residual network achieved a sensitivity of 90% and 97.1% for supraventricular and ventricular beats, respectively, and 81% for seizure detection.