In this study, the effects of applying a full oxygen blast furnace (FOBF) on carbon emissions were investigated by determining the ultimate minimum carbon consumption and a carbon metabolism calculation model. The results demonstrate that the minimum coke ratio of the top gas circulation-FOBF (TGR-FOBF) is significantly reduced (from 270 to 207 kg·thm −1 ) compared to that of the traditional ironmaking blast furnace (TBF). Owing to the complete recycling of the furnace top gas of the TGR-FOBF, the degree of direct reduction of TGR-FOBF significantly decreased to 0.14. The replacement of the TGR-FOBF with the three TBFs significantly reduced the CO 2 emissions, which were the highest at 1.761 t-CO 2 /t-CS. Most of the CO 2 emissions were generated by the direct combustion emissions (CDE) and direct process emissions (PDE), with a small amount generated by the electricity indirect emissions (EIE). The CO 2 emissions generated by CDE, PDE, and EIE were 0.872 t-CO 2 /t-CS, 0.840 t-CO 2 /t-CS, and 0.049 t-CO 2 /t-CS, respectively. As the amount of TGR-FOBF replaced with the three TBFs increased, the CO 2 emissions generated by the CDE and PDE significantly decreased. When all three TBFs were replaced with TGR–FOBF, the CO 2 emissions generated by the CDE and PDE decreased to extremely low levels of 0.267 t-CO 2 /t-CS and 0.065 t-CO 2 /t-CS, respectively.