Key result
In patients, intracoronary gamma-irradiation showed no evidence of a deleterious effect on angiographically normal uninjured reference segments at 6 months compared to placebo.
Why the study?
Does intracoronary gamma-irradiation cause deleterious effects on uninjured reference segments in patients treated for in-stent restenosis?
RCT (n=38)
blinded
randomized
Does intracoronary gamma-irradiation cause deleterious effects on uninjured reference segments in patients treated for in-stent restenosis?
Intracoronary gamma-irradiation for in-stent restenosis does not negatively impact adjacent uninjured reference segments at 6 months, as it induces positive remodeling (increased EEM area) that preserves lumen area.
Answers are grounded in this paper and cite their sources.
Supports safety of gamma-irradiation for in-stent restenosis without reference segment harm; extends RCT evidence on vascular remodeling.
BACKGROUND: The effects of endovascular irradiation on uninjured reference segments during the treatment of in-stent restenosis are unknown. METHODS AND RESULTS: In the Washington Radiation for In-Stent restenosis Trial (WRIST), patients with in-stent restenosis were first treated with conventional catheter-based techniques and then randomized (blinded) to receive either gamma-irradiation ((192)Ir) or a placebo (dummy seeds). We identified all patients in whom the active (n=19) or dummy seeds (n=19) extended >10 mm proximal and distal to the in-stent restenosis lesion. Serial (postirradiation and follow-up) external elastic membrane (EEM), lumen, and plaque and media (EEM-lumen) areas were measured (using intravascular ultrasound) every 1 mm over 5-mm-long reference segments that were 6 to 10 mm proximal and distal to the in-stent restenosis lesion. During follow-up, a similar small increase occurred in the plaque and media area in the proximal and distal reference segments in both (192)Ir and placebo patients. However, in the (192)Ir patients, an increase in both proximal and distal EEM area occurred; as a result, no change in lumen area occurred. Conversely, in the placebo patients, the proximal reference EEM area decreased, and no change occurred in the distal reference EEM area; this contributed to a decrease in lumen area. CONCLUSIONS: There was no evidence of a deleterious effect of gamma-irradiation on angiographically normal uninjured reference segments in the first 6 months after the treatment of in-stent restenosis.
No takes yet. Share an insight, caveat, or question.
Ahmed et al. (2000) conducted an RCT in in-stent restenosis (n=38). gamma-irradiation (192Ir) vs. placebo (dummy seeds) was evaluated on Changes in external elastic membrane, lumen, and plaque and media areas in uninjured reference segments. In patients, intracoronary gamma-irradiation showed no evidence of a deleterious effect on angiographically normal uninjured reference segments at 6 months compared to placebo.
Synapse has enriched 10 related papers. Consider them for comparative context: