Key result
Transesophageal echocardiography correctly diagnosed aortic dissection with 97% sensitivity and 100% specificity, outperforming computed tomography which correctly diagnosed only 67% of cases.
Why the study?
Does transesophageal echocardiography accurately diagnose and assess aortic dissection compared to computed tomography and gold standard methods?
Observational (n=61)
No
Does transesophageal echocardiography accurately diagnose and assess aortic dissection compared to computed tomography and gold standard methods?
Transesophageal echocardiography is a highly sensitive and specific imaging modality for the diagnosis and detailed anatomical assessment of aortic dissection.
Answers are grounded in this paper and cite their sources.
May aid rapid bedside aortic dissection diagnosis; leaves open comparative accuracy versus contemporary CT/MRI.
BACKGROUND: The value of transesophageal echocardiography in the assessment of patients with aortic dissection was studied. METHODS AND RESULTS: Group 1 (34 patients) represented all patients studied at our institution with this technique in whom aortic dissection was proven by aortography, surgery, or autopsy. Group 2 (27 patients) represented all patients studied with this technique at our institution in whom aortic dissection was excluded by aortography. Transesophageal echocardiography made a correct diagnosis of aortic dissection in 33 of 34 patients (sensitivity, 97%; specificity, 100%). It also correctly demonstrated the type of dissection in all 29 patients with aortographic or surgical proof. On the other hand, computed tomography scanning, performed in 24 of 34 patients in group 1, made a correct diagnosis in only 67% of patients and misclassified the type of dissection in 33%. Transesophageal echocardiography correctly identified involvement of the coronary arteries by aortic dissection in six of seven patients as well as absence of both left and right coronary artery involvement in 10 patients with aortic dissection. This technique was also useful in detecting communications between the true and false lumens, presence of thrombi in the false lumen, and, in two patients, localized dissection rupture with formation of a false aneurysm. In both groups 1 and 2, transesophageal echocardiography correctly identified patients with moderate to severe aortic regurgitation. CONCLUSIONS: Transesophageal echocardiography is very useful in the assessment of aortic dissection.
No takes yet. Share an insight, caveat, or question.
Ballal et al. (1991) conducted an observational in Aortic dissection (n=61). Transesophageal echocardiography vs. Computed tomography scanning was evaluated on Correct diagnosis of aortic dissection (sensitivity). Transesophageal echocardiography correctly diagnosed aortic dissection with 97% sensitivity and 100% specificity, outperforming computed tomography which correctly diagnosed only 67% of cases.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: