Intravascular catheters and implanted cardiac devices were common sources of infection in 155 patients with infective endocarditis, which had a 90-day mortality of 22.5%.
Observational (n=155)
Intravascular catheters and cardiac implantable devices are significant sources of infective endocarditis, frequently involving S. aureus and carrying high mortality.
Answers are grounded in this paper and cite their sources.
Device sources merit clinical vigilance in IE evaluation; extends observational data but leaves causal links and prevention open.
BACKGROUND: The relationship between invasive medical devices and infective endocarditis (IE) has not been comprehensively assessed. We describe our experience of patients with IE, with particular attention to the role of pre-existing intravascular catheters and implanted cardiac devices in the pathogenesis. METHODS: We performed a retrospective review of hospital records over a 10-y period (1997-2007), and included patients with 'definite' or 'possible' IE as per the modified Duke criteria. The complete electronic medical record was reviewed for the presence of intravascular devices prior to the onset of IE, including intravascular catheters and implanted cardiac devices (defibrillators and pacemakers). RESULTS: We identified 155 patients with IE. Infection involved a native valve in 124 (80%) patients and a prosthetic valve in 15 (9.7%). In the remaining 16 (10.3%) patients, infection was attributed to an implanted cardiac device. The most commonly identified source of infection was a central venous catheter, accounting for 17.4% of patients, followed by an implanted cardiac device in 10.3% of patients. Staphylococcus aureus was the most commonly isolated organism in catheter-associated IE and cardiac device-associated IE (31.9% and 62.5%, respectively). Thirty-five (22.5%) patients died within 90 days. Mortality was 31.9% in patients with IE caused by methicillin-resistant S. aureus (MRSA). CONCLUSIONS: Intravascular catheters and cardiac implantable devices are common sources of infection leading to IE, and the intracardiac devices themselves often become infected, with MRSA as the predominant pathogen.
No takes yet. Share an insight, caveat, or question.
Roig et al. (2012) conducted an observational in Infective endocarditis (n=155). Intravascular catheters and implanted cardiac devices was evaluated on Source of infection and 90-day mortality. Intravascular catheters and implanted cardiac devices were common sources of infection in 155 patients with infective endocarditis, which had a 90-day mortality of 22.5%.
Synapse has enriched 10 related papers. Consider them for comparative context: