Key result
Higher preprocedural aortic regurgitation grade (OR 7.00; 95% CI 2.76-17.8) and right ventricular fractional area change (OR 1.05; 95% CI 1.01-1.10) predicted increased stroke volume after TAVR.
Why the study?
Increased stroke volume is a prognosticator of severe AS after TAVR, but preprocedural echocardiographic predictors of increased stroke volume after TAVR remained to be investigated.
Do preprocedural echocardiographic parameters predict increased stroke volume after TAVR in patients with severe aortic stenosis?
Cohort (n=129)
Do preprocedural echocardiographic parameters predict increased stroke volume after TAVR in patients with severe aortic stenosis?
Odds Ratio: 7 (95% CI 2.76–17.8)
p-value: p=<0.001
Preprocedural echo parameters may predict post-TAVR SV increase; leaves open prospective validation before clinical use.
Aims: Increased stroke volume (SV) is a prognosticator of severe aortic stenosis (AS) after transcatheter aortic valve replacement (TAVR). This study aimed to investigate preprocedural echocardiographic predictors of increased SV after TAVR. Methods and results: Clinical and echocardiographic data were retrospectively analysed in 129 patients with severe AS who underwent TAVR (2013-2015). We compared the echocardiographic data and cardiac events between the decreased SV group (n=28) and the increased SV group (n=101). Univariate and multivariate analyses were used to assess the predictors of increasing SV. AS severity significantly diminished, left and right ventricular function improved, and SV index (SVi) increased after TAVR: aortic valve area index (0.46±0.13 vs. 1.18±0.33 cm2, p<0.001); aortic regurgitation (AR) grade (1.85±0.55 vs. 1.60±0.54, p<0.001); left ventricular ejection fraction (59.9±12.7 vs. 64.1±12.0%, p<0.001); right ventricular fractional area change (RVFAC) (48.8±11.9 vs. 53.3±14.0%, p<0.001); SV index (SVi) (46.7±11.0 vs. 52.8±12.0 ml/m2, p<0.001). Kaplan-Meier survival estimates suggested that the SVi increase was associated with the decreased cardiovascular events one year after TAVR (hazard ratio 4.08, 95% confidence interval [CI]: 1.32-12.7, p=0.02). On multivariate analysis, preprocedural AR grade (odds ratio [OR] 7.00, 95% CI: 2.76-17.8, p<0.001) and preprocedural RVFAC (OR 1.05, 95% CI: 1.01-1.10, p=0.011) correlated with the SV increase. Conclusions: Preprocedurally, greater AR and higher RVFAC could predict an increased SVi and thus the occurrence of fewer cardiac events. Preserved preprocedural RV systolic function is crucial for an increased SV after TAVR.
No takes yet. Share an insight, caveat, or question.
Shirakawa et al. (2019) conducted a cohort in Severe aortic stenosis (n=129). Preprocedural aortic regurgitation grade and right ventricular fractional area change was evaluated on Increased stroke volume after TAVR (OR 7.00, 95% CI 2.76-17.8, p=<0.001). Higher preprocedural aortic regurgitation grade (OR 7.00; 95% CI 2.76-17.8) and right ventricular fractional area change (OR 1.05; 95% CI 1.01-1.10) predicted increased stroke volume after TAVR.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: