Key result
Applying revised cutoff values for [I]/IC50 < 0.1 and [I2]/IC50 < 5 reduced the false negative rate for predicting clinically relevant digoxin drug interactions from 36% to 9%.
Why the study?
Do revised cutoff values for [I]/IC50 and [I2]/IC50 improve the prediction of clinically relevant P-glycoprotein related digoxin drug interactions?
Do revised cutoff values for [I]/IC50 and [I2]/IC50 improve the prediction of clinically relevant P-glycoprotein related digoxin drug interactions?
Revised in vitro cutoff values for P-glycoprotein inhibition significantly reduce false negative predictions for clinical digoxin drug interactions.
Answers are grounded in this paper and cite their sources.
May refine in vitro P-gp DDI screening for digoxin; leaves open clinical validation before practice impact.
The objective of this work was to further investigate the reasons for disconcordant clinical digoxin drug interactions (DDIs) particularly for false negative where in vitro data suggests no P-glycoprotein (P-gp) related DDI but a clinically relevant DDI is evident. Applying statistical analyses of binary classification and receiver operating characteristic (ROC), revised cutoff values for ratio of [I]/IC(50) < 0.1 and [I(2)]/IC(50) < 5 were identified to minimize the error rate, a reduction of false negative rate to 9% from 36% (based on individual ratios). The steady state total C(max) at highest dose of the inhibitor is defined as [I] and the ratio of the nominal maximal gastrointestinal concentration determined for highest dose per 250 mL volume defined [I(2)](.) We also investigated the reliability of the clinical data to see if recommendations can be made on values that would allow predictions of 25% change in digoxin exposure. The literature derived clinical digoxin interaction studies were statistically powered to detect relevant changes in exposure associated with digitalis toxicities. Our analysis identified that many co-meds administered with digoxin are cardiovascular (CV) agents. Moreover, our investigations also suggest that the presence of CV agents may alter cardiac output and/or kidney function that may act alone or are additional components to enhance digoxin exposure along with P-gp interaction. While we recommend digoxin as the probe substrate to define P-gp inhibitory potency for clinical assessment, we observed high concordance in P-gp inhibitory potency for calcein AM as a probe substrate.
No takes yet. Share an insight, caveat, or question.
Cook et al. (2009) studied Clinical digoxin drug interactions (DDIs). Revised cutoff values for [I]/IC50 < 0.1 and [I2]/IC50 < 5 vs. Individual ratios was evaluated on False negative rate for predicting clinically relevant digoxin drug interactions. Applying revised cutoff values for [I]/IC50 < 0.1 and [I2]/IC50 < 5 reduced the false negative rate for predicting clinically relevant digoxin drug interactions from 36% to 9%.
Synapse has enriched 10 related papers. Consider them for comparative context: