Answers are grounded in this paper and cite their sources.
The authors investigate and implement a novel model reference adaptive controller for correction of the rotor time constant used in the calculation of the slip frequency in indirect field oriented control of induction machines. The implementation of the controller is based on the machine air gap flux which is measured by detecting the third harmonic component of the stator pulse voltages. The proposed adaptive controller depends only on a single, easily measurable machine parameter estimate, i.e., the magnetizing inductance. A correction strategy to compensate for changes of the magnetizing inductance when changes in the air gap flux level occur is also proposed. This strategy is based on a function that relates the value of this inductance to the amplitude of the third harmonic stator voltage component. Verification of the validity and feasibility of the proposed technique is obtained from simulation and experimental results.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>
No takes yet. Share an insight, caveat, or question.
Moreira et al. (1993) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: