A listener with auditory neuropathy, an absence of subcortical neural synchrony, did not have electrophysiological frequency-following responses synchronized to an octave of musical notes, with fundamental frequencies ranging from 65 to 130 Hz. A control subject had robust responses that phaselocked to each note. Although auditory cortex may contribute to the scalp-recorded frequency-following response in healthy listeners, our results suggest this phenomenon depends on subcortical neural synchrony.
No takes yet. Share an insight, caveat, or question.
White‐Schwoch et al. (2020) studied this question.