Key result
Peripheral venous blood gas analysis for pH, bicarbonate, and base excess is clinically interchangeable with arterial values in non-shocked patients, with a mean pH difference of 0.035.
Why the study?
Can peripheral venous blood gas analysis replace arterial blood gas analysis for measuring pH, pCO2, bicarbonate, and base excess in adult emergency department patients?
Systematic Review
Can peripheral venous blood gas analysis replace arterial blood gas analysis for measuring pH, pCO2, bicarbonate, and base excess in adult emergency department patients?
Mean Difference: 0.035
Venous pH, bicarbonate, and base excess have sufficient agreement to be clinically interchangeable with arterial values in non-shocked patients, whereas venous pCO2 agreement is too poor for one-off testing but may be useful for screening or trending.
May support venous sampling to reduce arterial punctures in ED; leaves open precise agreement thresholds for routine substitution.
The objectives of the present review are to describe the agreement between variables on arterial and venous blood gas analysis (in particular pH, pCO(2) , bicarbonate and base excess) and to identify unanswered questions. MEDLINE search of papers published from 1966 to January 2010 for studies comparing arterial and peripheral venous blood gas values for any of pH, pCO(2) , bicarbonate and base excess in adult patients with any condition in an emergency department setting. The outcome of interest was mean difference weighted for study sample size with 95% limits of agreement. The weighted mean arterio-venous difference in pH was 0.035 pH units (n= 1252), with narrow limits of agreement. The weighted mean arterio-venous difference for pCO(2) was 5.7 mmHg (n= 760), but with 95% limits of agreement up to the order of ±20 mmHg. For bicarbonate, the weighted mean difference between arterial and venous values was -1.41 mmol/L (n= 905), with 95% limits of agreement of the order of ±5 mmol/L. Regarding base excess, the mean arterio-venous difference is 0.089 mmol/L (n= 103). There is insufficient data to determine if these relationships persist in shocked patients or those with mixed acid-base disorders. For patients who are not in shock, venous pH, bicarbonate and base excess have sufficient agreement to be clinically interchangeable for arterial values. Agreement between arterial and venous pCO(2) is too poor and unpredictable to be clinically useful as a one-off test but venous pCO(2) might be useful to screen for arterial hypercarbia or to monitor trends in pCO(2) for selected patients.
No takes yet. Share an insight, caveat, or question.
Anne‐Maree Kelly (2010) conducted a systematic review in Any condition in an emergency department setting. Peripheral venous blood gas analysis vs. Arterial blood gas analysis was evaluated on Mean arterio-venous difference in pH (MD 0.035). Peripheral venous blood gas analysis for pH, bicarbonate, and base excess is clinically interchangeable with arterial values in non-shocked patients, with a mean pH difference of 0.035.
Synapse has enriched 3 closely related papers on similar clinical questions. Consider them for comparative context: