Demonstrates improved paracetamol detection in drug formulations, suggesting enhanced sensitivity.
This new and simple amperometric method takes advantage of the electroactivity of V 2 O 5 in the oxidation of paracetamol (PCM) on a carbon paste electrode (CPE). With the modified electrode (V OX /CPE) the anode peak current for PCM was more than 100 % than that of the unmodified electrode. The electrode surface was characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) and scanning electron microscopy (SEM). The amperograms were measured at +0.70 V (vs Ag/AgCl), and the calibration curve indicated a detection limit of 0.06 μmol/L and a sensitivity of 1.93 μA/μM cm 2 . The modified electrode was used in the detection of solid drugs such as PCM tablets and children's syrup with acceptable results.
No takes yet. Share an insight, caveat, or question.
Nagles et al. (2024) studied this question.