Answers are grounded in this paper and cite their sources.
PURPOSE: To report a technique to create an extra-large vascular plug for occlusion of a large distal false lumen in chronic aortic dissection. TECHNIQUE: The "candy-plug" technique is demonstrated in a 58-year-old multimorbid man with a history of complicated acute type B aortic dissection and a 9-cm chronic thoracic false lumen aneurysm. The patient underwent a staged repair with a cervical debranching procedure as a first step and a thoracic endovascular aortic repair from the innominate artery to the celiac artery as a second step. To occlude the large false lumen from a distal route, a stent-graft was modified on-table with a diameter-restricting suture, giving it a wrapped candy-like shape. This plug was deployed into the false lumen, and the remaining opening was occluded with a standard vascular plug. On 3-month follow-up imaging, the thoracic false lumen aneurysm remained completely thrombosed. CONCLUSION: The candy-plug technique can facilitate complete occlusion of chronic thoracic false lumen aneurysm by prohibiting distal false lumen backflow.
No takes yet. Share an insight, caveat, or question.
Kölbel et al. (2013) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: