Key result
Microvolt T-wave alternans is an emerging prognostic tool for risk stratification to guide prophylactic implantable cardioverter-defibrillator therapy in patients with cardiomyopathy.
Why the study?
Does microvolt T-wave alternans measurement predict sudden cardiac death in patients with cardiomyopathy?
Does microvolt T-wave alternans measurement predict sudden cardiac death in patients with cardiomyopathy?
Microvolt T-wave alternans is an emerging non-invasive tool that may improve sudden cardiac death risk stratification in cardiomyopathy patients beyond ejection fraction.
Answers are grounded in this paper and cite their sources.
May refine SCD risk stratification in cardiomyopathy; leaves open need for prospective validation before guiding ICD therapy.
PURPOSE OF REVIEW: Sudden cardiac death remains a major cause of mortality among patients with cardiomyopathy and implantable cardioverter-defibrillator therapy has been shown to improve survival in these patients. Effective use of prophylactic implantable cardioverter-defibrillator therapy requires accurate risk stratification beyond assessment of ejection fraction, however. Repolarization alternans is a harbinger of ventricular arrhythmias and its measurement from body-surface recordings, also known as microvolt T-wave alternans, is emerging as an effective prognostic tool in these patients based on recent clinical trials. RECENT FINDINGS: We review the pathogenesis and determinants of repolarization alternans. The current techniques for measuring T-wave alternans from the body surface are compared, including the spectral and modified moving average methods. Recent clinical trials evaluating the prognostic utility of T-wave alternans in patients with ischemic and nonischemic cardiomyopathy and no prior arrhythmic events are summarized. The findings of these studies are discussed in the context of implantable cardioverter-defibrillator prophylaxis. Body-surface T-wave alternans is an evolving technique and its limitations are presented along with approaches to improve its predictive accuracy. SUMMARY: Risk stratification with T-wave alternans has the potential to guide prophylactic implantable cardioverter-defibrillator therapy in a growing population of patients with cardiomyopathy.
No takes yet. Share an insight, caveat, or question.
Chauhan et al. (2006) conducted a review in Cardiomyopathy. Microvolt T-wave alternans was evaluated on Sudden cardiac death. Microvolt T-wave alternans is an emerging prognostic tool for risk stratification to guide prophylactic implantable cardioverter-defibrillator therapy in patients with cardiomyopathy.