Key result
Artificial gravity of 2-g at the feet induced via a short-arm human centrifuge evoked autonomic blood pressure regulatory controls analogous to standing, with no significant difference in baroreflex sensitivity.
Why the study?
Does artificial gravity induced via short-arm human centrifuge evoke autonomic blood pressure regulatory controls analogous to standing in healthy participants?
Does artificial gravity induced via short-arm human centrifuge evoke autonomic blood pressure regulatory controls analogous to standing in healthy participants?
Absolute Event Rate: 7.52% vs 10.4%
p-value: p=0.79
Artificial gravity of 2-g at the feet created via short-arm human centrifuge evokes blood pressure regulatory controls analogous to standing, suggesting potential utility for mitigating microgravity-induced orthostatic intolerance.
SAHC at 2 g evokes autonomic BP control akin to standing; leaves open whether it prevents postflight orthostatic intolerance.
Autonomic control of blood pressure is essential towards maintenance of cerebral perfusion during standing, failure of which could lead to fainting. Long-term exposure to microgravity deteriorates autonomic control of blood pressure. Consequently, astronauts experience orthostatic intolerance on their return to gravitational environment. Ground-based studies suggest sporadic training in artificial hypergravity can mitigate spaceflight deconditioning. In this regard, short-arm human centrifuge (SAHC), capable of creating artificial hypergravity of different g-loads, provides an auspicious training tool. Here, we compare autonomic control of blood pressure during centrifugation creating 1-g and 2-g at feet with standing in natural gravity. Continuous blood pressure was acquired simultaneously from 13 healthy participants during supine baseline, standing, supine recovery, centrifugation of 1-g, and 2-g, from which heart rate (RR) and systolic blood pressure (SBP) were derived. The autonomic blood pressure regulation was assessed via spectral analysis of RR and SBP, spontaneous baroreflex sensitivity, and non-linear heart rate and blood pressure causality (RR↔SBP). While majority of these blood pressure regulatory indices were significantly different (p0.05) was observed in the same indices during 2-g centrifugation compared to standing. The findings of the study highlight the capability of artificial gravity (2-g at feet) created via SAHC towards evoking blood pressure regulatory controls analogous to standing, therefore, a potential utility towards mitigating deleterious effects of microgravity on cardiovascular performance and minimizing post-flight orthostatic intolerance in astronauts.
No takes yet. Share an insight, caveat, or question.
Verma et al. (2018) studied Healthy participants (n=13). Artificial gravity via short-arm human centrifuge vs. Standing in natural gravity was evaluated on Spontaneous baroreflex sensitivity (up slope, ms/mmHg) (p=0.79). Artificial gravity of 2-g at the feet induced via a short-arm human centrifuge evoked autonomic blood pressure regulatory controls analogous to standing, with no significant difference in baroreflex sensitivity.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: