Why the study?
Both 99mTc-DTPA and 51Cr-EDTA are widely used to measure GFR, but few direct comparisons exist, making assessment relevant given 51Cr-EDTA shortages.
Does 99mTc-DTPA provide comparable plasma clearance measurements to 51Cr-EDTA in adult patients referred for routine GFR measurement?
Cross-Sectional (n=56)
Does 99mTc-DTPA provide comparable plasma clearance measurements to 51Cr-EDTA in adult patients referred for routine GFR measurement?
Answers are grounded in this paper and cite their sources.
99mTc-DTPA can safely replace 51Cr-EDTA for routine GFR measurement, as there are no clinically relevant differences in plasma clearance between the two tracers.
Both 99mTc-DTPA and 51Cr-EDTA are widely used to determine glomerular filtration rate (GFR), but few direct comparative studies exist. The shortage of 51Cr-EDTA makes a direct comparison highly relevant. The aim of the study was to investigate if there is any clinically relevant difference between plasma clearance of 99mTc-DTPA and 51Cr-EDTA. Patients ≥18 years of age referred for routine GFR measurement by 51Cr-EDTA were prospectively enrolled. The two tracers (10 MBq 99mTc-DTPA (CaNa3-DTPA) and 2.5 MBq 51Cr-EDTA) were intravenously injected at time zero. A standard 4-sample technique was applied with samples collected at 180, 200, 220 and 240 min, if the estimated GFR (eGFR) was ≥30 mL/min. A comparison of single-sample GFR based on the 200 min sample was also conducted. Fifty-six patients were enrolled in the study. All patients had an estimated GFR >30 mL/min/1.73 m2. No patients suffered from ascites or significant oedema. The mean 51Cr-EDTA plasma clearance was 82 mL/min (range 16–226). The plasma clearances determined by the two methods were highly correlated (r = 0.993). The plasma clearance was significantly higher when measured by 99mTc-DTPA than by 51Cr-EDTA (p = 0.01), but the numerical difference was minimal (mean difference 1.4 mL/min; 95% limits of agreement (LOA) –6.6 to 9.4). The difference between the two methods was independent of the level of renal function. Similar results were found for one-sample GFR. No clinically relevant differences were found between the plasma clearance of 99mTc-DTPA and that of 51Cr-EDTA. Therefore, 99mTc-DTPA can replace 51Cr-EDTA when needed.
No takes yet. Share an insight, caveat, or question.
Andersen et al. (2019) conducted a cross-sectional in referred for routine GFR measurement (n=56). 99mTc-DTPA vs. 51Cr-EDTA (2.5 MBq) was evaluated on plasma clearance (MD 1.4 mL/min, 95% CI -6.6 to 9.4, p=0.01).
Synapse has enriched 10 related papers. Consider them for comparative context: